PROFINET interface
9.9.3.33 Module 20: free resolution
PROFINET module identifier
Module-ID
Submodule-ID
Description
Free resolution is used when the resolutions set in the standard are not appropriate. If a free
resolution is used, this must be activated in module 1c for the position or in module 10a for
the velocity.
Both module 20 and module 1c or 10a must be set for configuration of the free resolution.
Parameters
Parameter
Description
This module allows the output
a
measurement values for position and
Free resolu-
velocity to be freely scaled.
tion position
The parameters apply to all interfaces
b
for which the "free resolution" resolu-
tion was selected. The internal
measurement value is multiplied by the
set value on the basis of (mm/1000).
Example: Value "3000" means that in
the event of a change in the measure-
ment value by 3 mm, the position value
Free resolu-
in the binary code changes by binary 1.
tion velocity
Due to the free resolution in the exam-
ple, an internal measurement value of
3333 mm gives an output value of
"1111".
The resolution of the "Offset", "Preset"
and "Limit values" parameters is not
affected by free resolution.
Parameter length: 4 bytes
91
1020
1
Rel.
Data
Value
addr.
type
unsign
0 ... 1
5 ...50000
16 bit
unsign
2 ... 3
5 ...50000
16 bit
AMS
348i
Default
Unit
metr.
Inch
3
1000
mm/10
in/10
1000
(mm/10
3
)/s (in/10
Leuze electronic
CR to
module
5
1c
5
)/s 10a