9.9.3.32 Module 18: Other
PROFINET module identifier
Module-ID
Submodule-ID
Description
General operating parameters such as display language, lighting and contrast, password,
heating control, etc. are set in this module.
Parameters
Parameter
Description
a
Language selection for the display. 
A language which was selected via the
Language
display is overwritten by this
selection
parameter.
b
Off after 10 min. or always on.
Display
illumination
Contrast setting of the display.
c
The contrast changes under extreme
Display 
ambient temperatures and can be
contrast
adjusted with this parameter.
d
Password protection on/off.
Password
protection
Specifies the password.
e
Password protection must be on.
Password
Defines a switch-on/switch-off range
f
for the heating control. The extended
switch-on/switch-off range for heating
may provide relief in the event of con-
densation problems. There is no guar-
antee that no condensation will occur
Heating
on the optics in the extended switch-
control
on/switch-off range due to the limited
heating capacity.
This parameter is available as stan-
dard, but functions only for devices with
integrated heating (AMS 348 ... H).
Parameter length: 4 bytes
Input data
None
Output data
None
Leuze electronic
1018
1
Rel.
Data
Value
addr.
type
000=0: English
0.0
001=1: German
...
Bit
010=2: Italian
0.2
011=3: Spanish
100=4: French
0: Off after 10 min.
0.3
Bit
1: Always on
0.4
000=0: Weak
...
Bit
001=1: Medium
0.5
010=2: Strong
0: OFF
0.7
Bit
1: ON
unsign
1...2
0000 ... 9999
16 bit
0 = Standard 
(10 °C ... 15 °C)
3.0
Bit
1 = Extended 
(30 °C ... 35 °C)
AMS
348i
PROFINET interface
Default
Unit
CR to
module
metr. Inch
0
0
1
0
0000
0
90