Leuze electronic AMS 348i Manual page 88

Optical laser measurement system
Table of Contents

Advertisement

PROFINET interface
9.9.3.28 Module 13: Static velocity limit value 3
PROFINET module identifier
Module-ID
Submodule-ID
Description
The static velocity limit value 3 function compares the current velocity with a velocity
stored in the configuration. This occurs in the configured range, which is defined by range
start and range end.
Notice!
Further explanations on the "Range start" and "Range end" parameters see chapter 9.9.3.26
"Module 11: Static velocity limit value 1".
Parameters
Parameter
Description
a
Condition for the "velocity limit value 3"
signal, which applies to the output
Switching
(module 4/5) and the status bit (module
mode
16).
Selection of direction-dependent or
b
direction-independent limit value
Direction
checking.
selection
c
Limit value is compared to the current
Velocity limit
velocity.
value 3
d
Relative shift to prevent signal
Velocity
bouncing.
hysteresis 3
e
The velocity limit value is monitored
Limit value 3
beginning at this position.
range start
f
The velocity limit value is monitored up
Limit value 3
to this position.
range end
Input data
None
Output data
None
85
1013
1
Rel.
Data
Value
addr.
type
0: Value greater than limit
0.0
Bit
1: Value less than limit
0: Direction independent
0.1
Bit
1: Direction dependent
unsign
1...2
0 ... 20000
16 bit
unsign
3...4
0 ... 20000
16 bit
sign
5...8
-999999 ... +999999
32 bit
9
sign
...
-999999 ... +999999
32 bit
12
Parameter length: 13 bytes
AMS
348i
Default
Unit
CR to
module
metr.
Inch
0
0
(in/
0
mm/s
100)
/s
(in/
100
mm/s
100)
/s
in/
0
mm
100
in/
0
mm
100
Leuze electronic
16f

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents