6.4

Mounting the reflector

6.4.1

General information

Self-adhesive reflective tapes
The reflective tapes of the "Reflective tape ...x...-S" self-adhesive series must be affixed
to a flat, clean and grease-free surface. We recommend using a separate metal plate, which
is to be provided on-site.
As described in table 6.1, the reflective tape must be angled.
Reflective tapes on metal
The reflective tapes of the "Reflective tape ...x...-M" series are provided with corresponding
mounting holes. Spacer sleeves are provided in the packet for achieving the necessary pitch
angle. For further information see table 6.1.
Heated reflectors
The reflective tapes of the "Reflective tape ...x...-H" series are provided with corresponding
mounting holes. Due to the voltage supply affixed on the rear, the reflector cannot be
mounted flat. Included in the package are four distance sleeves in two different lengths. Use
the distance sleeves to achieve a base separation to the wall as well as the necessary pitch
for avoiding surface reflection. For further information see table 6.1.
The reflector is provided with a 2 m-long connection cable for supplying with 230 V AC.
Connect the cable to the closest power outlet. Observe the current consumptions listed in
the specifications.
Attention!
Connection work must be carried out by a certified electrician.
6.4.2
Mounting the reflector
The combination of laser measurement system and reflective tape/reflector is mounted so
that the laser light spot hits the tape as centered as possible and without interruption.
For this purpose, use the alignment elements provided on the AMS 348i... (see chapter 5.2
"Mounting the AMS 348i"). If necessary, remove the protective foil from the reflector.
Attention!
The "TOP" label mounted on the reflectors should be aligned the same as the connections
of the AMS 348i.
Example:
If the AMS
the reflector is also on the top. If the AMS
on the side, the "TOP" label of the reflector is also on the side.
Leuze electronic
348i
is mounted so that the M 12 connections are on the top, the "TOP" label of
348i
is mounted so that the M 12 connections are
AMS
348i
Reflectors