Pdo Communication Parameter Record; Pdo Communication Mapping Parameter - Festo Compact Performance Series Programming And Diagnosis

Valve terminal with direct link
Hide thumbs Also See for Compact Performance Series:
Table of Contents

Advertisement

2. Commissioning

2.3.1 PDO communication parameter record

The following objects are defined in the "Receive" PDO
communication parameter
(values and examples: module ID = 1).
Communication
profile
Index
Objekt name
Object
(hex)
sSymbolic
designation
1400
RECORD
Communication
parameter for
receive PDO

2.3.2 PDO communication mapping parameter

PLEASE NOTE
Variable mapping is not supported.
The following objects are defined in the "Receive" PDO
mapping parameter.
Communication
profile
Index
Object name
Object
(hex)
symbolic
designation
1600
ARRAY
Mapping
parameter for
receive PDO
2-12
Object
Object
Values/
type
attributes
subindex
PDOComm
ro
"0"=02
parameter
"1"=01 02 00 00
"2"=FF
Object
Object
Values/
type
attributes
subindex
PDOComm
ro
"0"= 02
parameter
"1"= 08 01 00 62
"2"= 08 02 00 62
Explanation of values
= Number of entries
= COB-ID 200 +
module ID
Transmiss. type
FF = acyclic,
asynchronous
Explanation of values
= Number of available
output
bytes
= coils 0 -7
= coils 8 - 15
CP-CO 9801NH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpv series

Table of Contents