3. Diagnosis
3.3 Testing the valves
WARNING
Before starting the test switch off the compressed
air supply for the CP valve terminal.
You will thereby avoid undesired or dangerous move-
ments of the actuators.
CAUTION
• The test function runs automatically in the CP
• Program-technical lockings or further switching
The CP valve terminal offers the following test routines:
Test routine
Parallel
Serial
Switch on all
valves
CP-CO 9801NH
valve terminal. All the valves are switched on/off
cyclically.
conditions will not be taken into account.
Meaning
All the valves of a byte are switched on/off at
one second intervals. Switching is made
continuously from byte 0 to byte 1 and vice versa.
All the valves of a byte are switched on/off one
after the other at one second intervals.
All valves are switched on.
3-7