5.8
Configuring a network (NetPro) for PG/PC
5.8.1
Integrating PG/PC into NetPro
Requirements
The following requirements for integrating a PG/PC must be met:
● The NCU is integrated in the S7 project using HW Config (see: Inserting SINUMERIK NCU
to the HW Config (Page 53)).
● The properties of the interfaces are configured (see: Configuring interfaces (Page 56)).
● The machine control panel is inserted (see: Modifying machine control panel in OB100
(Page 89)).
● The configuration has been saved and compiled (see: End the hardware configuration and
load it to the PLC (Page 69)).
● A PLC program has been created.
Inserting PG/PC in the S7 project
To perform routing functions and permit the communication between PG/PC ↔ HMI via
Ethernet, a PG/PC must be included in the SIMATIC Manager under NetPro and the interfaces
configured.
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
5.8 Configuring a network (NetPro) for PG/PC
PLC commissioning