Procedure:
1. To create a commissioning archive, select: "Commissioning" operating area → forward key
→ "Commissioning archives" → "Creating a commissioning archive" option:
2. Select the data to be backed up:
– NC data: With/without compensation data
– PLC data
– Drive data: Binary/ASCII
– HMI data: All/selection
3. Enter an archive name.
4. The following directories are offered as a storage location for the archive:
– Archive/user or Archive/manufacturer
– All configured logical drives (USB, network drives)
Note
USB FlashDrive
USB FlashDrives are not suitable as persistent memory media.
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
Absolute path specification: /user/sinumerik/data/archive or /oem/sinumerik/data/
archive
Saving and managing data
11.1 Saving data
349