8.22 ^BY BAR CODE FIELD DEFAULT

Format: ^BYw,r,h
w = Module width (in dots)
1 to 10
Default: "Narrow bar width/module size (dots)" in the default setting file
When omitted: Previous ^BY value
r = Wide bar to narrow bar width ratio
2.0 to 3.0 (Pitch: 0.1)
Default: "Wide bar to narrow bar ratio" in the default setting file
When omitted: Previous ^BY value
h = Bar code height (in dots)
203-dpi printer: LE840
1 to 800 dots
300-dpi printer: LE850
1 to 1200 dots
Default: "Default bar code height (dots)" in the default setting file
When omitted: Value of ^BY
* If the value after dot-to-mm conversion exceeds 100 mm, it is corrected to 100 mm.