8.114 ^RS SET UP RFID PARAMETERS

Format: ^RSt,p,v,n,e,a,c,s
t = Tag type
When UHF module (U2) is installed:
8 : EPC Class 1, Generation 2 (U2)
* If a option other than the above is selected, operation is performed with "EPC Class 1 Generation
2."
When HF module (H1, H2) is installed:
C or 2: TagIt
D or 3: Icode
F or 5: ISO 15693
* If an option other than the above is selected, operation is performed with "ISO 15693."
When omitted: Determined based on the PCL system mode setting information
For H1
For H2
For U2
p = Read/write position
- Label length to 0 to label length
When omitted: 0
*1 When the value is negative, the media is fed backward to the write/read position.
*2 When the value is positive, the media is fed forward to the write/read position.
*3 If the feed distance is 3 mm or less, a feed is not made.
v = Void pattern length (unsupported)
* This parameter is ignored.
n = Number of retries
0 to 10
When omitted: 3
*1 A value exceeding 10 is corrected to 10.
*2 Same as the number of retries of ^RI, ^RR, ^RT, and ^WT.
e = Error handling (unsupported)
*1 This parameter is ignored.
*2 When an error occurs, it stops the operation.
a = Signals from applicator (unsupported)
* This parameter is ignored.
c = Pre-read tag (Unsupported)
* This parameter is ignored.
s = Void print speed (unsupported)
* This parameter is ignored.
(H1)
(H1)
(H1, H2)
: ISO 15693
: ISO 15693
: EPC Class 1, Generation 2