Vent or Isolation Valve
Use the following instructions and Figure 5-14 to replace the vent () or isolation valve
().
1.
Remove the chassis and separate the chassis. See "Chassis" on page 5-11.
2.
Put the control panel () on a flat work surface upside down, using support blocks
to keep it raised above the surface.
3.
Disconnect the HF-2 gland () to the valve ( or ).
4.
Remove the two hex nuts () that secures the valve bracket () to the control
panel ().
5.
Remove the two screws () that secures the valve () to the valve bracket ().
6.
Install the new valve with two screws () and lock washers ().
7.
Put the chassis together and put into the case. See "Chassis" on page 5-11.
1
5
6
9
2
10
7
8
4
Figure 5-14. Isolation and Vent Valve Replacement