Vent or Isolation Valve

Use the following instructions and Figure 5-14 to replace the vent () or isolation valve
().
1.
Remove the chassis and separate the chassis. See "Chassis" on page 5-11.
2.
Put the control panel () on a flat work surface upside down, using support blocks
to keep it raised above the surface.
3.
Disconnect the HF-2 gland () to the valve ( or ).
4.
Remove the two hex nuts () that secures the valve bracket () to the control
panel ().
5.
Remove the two screws () that secures the valve () to the valve bracket ().
6.
Install the new valve with two screws () and lock washers ().
7.
Put the chassis together and put into the case. See "Chassis" on page 5-11.
1
5
6
9
2
10
7
8
4
Figure 5-14. Isolation and Vent Valve Replacement
Intensifier Maintenance
Intensifier Part Replacement
3
4
11
12
1
5
hbx022.eps
5-31