Download Print this page

Fluke Calibration TST-40M-HC40 Instructions Manual

High-pressure test station

Advertisement

Quick Links

Introduction
The Fluke TST-40M-HC40 Test Station and TST-100M High-Pressure Test Station (the Product) are
accessories that connect Devices Under Test (DUTs) to pressure controllers for calibration.
TST-40M-HC40 has a maximum working pressure of 44 MPa (6400 psi).
TST-100M has a maximum working pressure of 110 MPa (16000 psi).
How to Contact Fluke Calibration
To contact Fluke Calibration, call one of the following telephone numbers:
Technical Support USA: 1-877-355-3225
Calibration/Repair USA: 1-877-355-3225
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31-40-2675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566
China: +86-400-810-3435
Brazil: +55-11-3759-7600
Anywhere in the world: +1-425-446-6110
To see product information and download the latest manual supplements, visit Fluke Calibration's website at
www.flukecal.com.
To register your product, visit
5007301
PN
July 2018
©2018 Fluke Corporation. All rights reserved.
All product names are trademarks of their respective companies. Specifications are subject to change without notice.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
http://flukecal.com/register-product
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
TST-40M-HC40
High-Pressure Test Station
.
ООО «Флюк СИАЙЭС»
125167, г. Москва, Ленинградский
проспект дом 37,
корпус 9, подъезд 4, 1 этаж
Test Station
TST-100M
Instructions
1

Advertisement

loading

Summary of Contents for Fluke Calibration TST-40M-HC40

  • Page 1 • China: +86-400-810-3435 • Brazil: +55-11-3759-7600 • Anywhere in the world: +1-425-446-6110 To see product information and download the latest manual supplements, visit Fluke Calibration’s website at www.flukecal.com. To register your product, visit http://flukecal.com/register-product 5007301 July 2018 ©2018 Fluke Corporation. All rights reserved.
  • Page 2: Safety Information

    TST-40M-HC40 / TST-100M Instructions Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. WWarning To prevent personal injury: •...
  • Page 3: Box Contents

    • Instructions TST-40M-HC40 Note JIC #4 and AN4 are not identical, but the parts in these products are interchangeable. The components of the Product are shown in Table 2. Table 2. TST-40M-HC40 Features and Components ifg001.eps Number Item/Function  Collar ...
  • Page 4 TST-40M-HC40 / TST-100M Instructions TST-100M The components of the Product are shown in Table 3. Table 3. TST-100M Features and Components ifg002.eps Number Item/Function  DUT Port  Hose  Gland Nut and Collar...
  • Page 5: Operation

    This section explains how to set up the Product. TST-40M-HC40 To set up the TST-40M-HC40: 1. Install one of the included hose adapter fittings to the TEST port on the rear of the pressure controller. If using NPT, wrap PTFE tape on the NPT threads. If using BSP or SAE, make sure that the seal is on the BSP or SAE side of the adapter.
  • Page 6: Specifications

    TST-40M-HC40 / TST-100M Instructions Specifications Operating Temperature ......-20 °C to +50 °C Storage Temperature ......-20 °C to +70 °C Operating Humidity........5 % to 95 % relative humidity, non-condensing Wetted Materials TEST-40M-HC40 ........ Stainless Steel, Nitrile, Nylon TEST-100M ........Stainless Steel, Acetal TST-40M-HC40 Pressure Range .........

This manual is also suitable for:

Tst-100m