Fluke Calibration 5522A Getting Started

Fluke Calibration 5522A Getting Started

Multi-product calibrator
Hide thumbs Also See for 5522A:

Advertisement

Quick Links

5522A
Multi-Product Calibrator
Getting Started
PN 3795091
January 2011
© 2011 Fluke Corporation. All rights reserved. Printed in USA. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke Calibration 5522A

  • Page 1 5522A Multi-Product Calibrator Getting Started PN 3795091 January 2011 © 2011 Fluke Corporation. All rights reserved. Printed in USA. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or...
  • Page 3 OPERATOR SAFETY SUMMARY WARNING HIGH VOLTAGE is used in the operation of this equipment LETHAL VOLTAGE may be present on the terminals, observe all safety precautions! To avoid electrical shock hazard, the operator should not electrically contact the output HI or sense HI terminals or circuits connected to these terminals. During operation, lethal voltages of up to 1020 V ac or dc may be present on these terminals.
  • Page 5: Table Of Contents

    Placement and Rack Mounting.............. 9 Cooling Considerations ................. 9 Where to Go from Here ................. 10 Instruction Manuals ................11 5522A Getting Started Manual ............11 5522A Operators Manual ..............11 General Specifications ................11 Detailed Specifications ................12 DC Voltage ..................12 DC Current ..................
  • Page 6 5522A Getting Started Harmonics (2 to 50 )............... 25 AC Voltage (Sine Wave) Extended Bandwidth........26 AC Voltage (Non-Sine Wave)............27 AC Voltage, DC Offset............... 29 AC Voltage, Square Wave Characteristics........29 AC Voltage, Triangle Wave Characteristics (typical)......29 AC Current (Non-Sine Wave) ............30 AC Current, Square Wave Characteristics (typical) ......
  • Page 7 List of Tables Table Title Page Symbols..................... 2 Standard Equipment.................. 6 Line Power Cord Types Available from Fluke ........... 9...
  • Page 8 5522A Getting Started...
  • Page 9 List of Figures Figure Title Page 5522A Multi-Product Calibrator ..............1 RS-232 Remote Connections..............5 How to Access the Fuse and Select Line Voltage........7 Line Power Cord Types Available from Fluke ........... 9 Allowable Duration of Current >11 A ............14...
  • Page 10 5522A Getting Started...
  • Page 11: Getting Started

    Getting Started Introduction The 5522A Multi-Product Calibrator (referred to throughout this manual as either "the Product" or "the Calibrator") is a fully programmable precision source of the following: • DC voltage from 0 to ±1020 V. • AC voltage from 1 mV to 1020 V, with output from 10 Hz to 500 kHz.
  • Page 12: Safety Information

    Pressure measurement when used with Fluke 700 Series pressure modules. • 10 MHz reference input and output. Use this to input a high-accuracy 10 MHz reference to transfer the frequency accuracy to the 5522A, or to synchronize one or more additional 5522A Calibrators to a master 5522A. •...
  • Page 13: How To Contact Fluke

    Multi-Product Calibrator How to Contact Fluke XW Warning To prevent personal injury: • Use the Product only as specified, or the protection supplied by the Product can be compromised. To prevent possible electrical shock, fire, or personal injury: • Do not use the Product if it operates incorrectly. •...
  • Page 14: Overload Protection

    The Calibrator may be operated at the front panel in the local mode, or remotely using RS-232 or IEEE-488 ports. For remote operations, several software options are available to integrate 5522A operation into a wide variety of calibration requirements. Local Operation...
  • Page 15: Remote Operation (Rs-232)

    Windows-based software such as 5500/CAL or MET/CAL. The 5500/CAL Software includes more than 200 example procedures covering a wide range of test tools the 5522A can calibrate. (See Chapter 6 in the Operators Manual for a discussion of the RS- 232 commands.) The SERIAL 2 TO UUT serial data port connects a UUT to a PC or terminal via the 5522A (see Figure 2).
  • Page 16: Unpack And Inspect

    5522A Operators Manual, “Accessories” for more information. Report any shortage to the place of purchase or to the nearest Fluke Service Center (see “How to Contact Fluke” in this manual). A performance test is provided in Chapter 7 of the 5522A Operators manual, “Maintenance.”...
  • Page 17: How To Select Line Voltage

    You can operate the 5522A Calibrator from one of four line voltage settings: 100 V, 120 V, 200 V, and 240 V (47 Hz to 63 Hz). To check the line voltage setting, note the voltage setting visible through the window in the power line fuse compartment cover (Figure 3).
  • Page 18: Connecting To Line Power

    The calibrator is shipped from the factory for nominal operation at 60 Hz line frequency. If you are using 50 Hz line voltage, you should re-configure the 5522A for optimal performance at 50 Hz. To do so, from the front panel, go into SETUP, INSTMT SETUP, OTHER SETUP, and then push the softkey under MAINS to change to 50 Hz.
  • Page 19: Placement And Rack Mounting

    (61-cm) deep equipment rack. For bench-top use, the calibrator is equipped with non- slipping, non-marring feet. To mount the calibrator in an equipment rack, use the 5522A Rack Mount Kit, Model Y5537. Instructions for rack mounting the calibrator are packed with the rack mount kit.
  • Page 20: Where To Go From Here

    Calibrating an Oscilloscope: Chapters 9, or 10, “SC-600 Oscilloscope Calibration Option”, or “SC-1100 Oscilloscope Calibration Option” • Calibrating Power Quality Equipment: Chapter 11, “PQ Option” • Accessories to the 5522A Calibrator: Chapter 8, “Accessories” • Performance Specifications: Chapter 1, “Introduction and Specifications”...
  • Page 21: Instruction Manuals

    The following tables list the 5522A specifications. All specifications are valid after allowing a warm-up period of 30 minutes, or twice the time the 5522A has been turned off. (For example, if the 5522A has been turned off for 5 minutes, the warm-up period is 10 minutes.) All specifications apply for the temperature and time period indicated.
  • Page 22: Detailed Specifications

    Weight (without options)........22 kg (49 lb) Absolute Uncertainty Definition ......The 5522A specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total specification of the 5522A for the temperature range indicated.
  • Page 23: Dc Current

    T-I minutes any 60 minute period where T is the temperature in °C (room temperature is about 23 °C) and I is the output current in amperes. For example, 17 A, at 23 °C could be provided for 60-17-23 = 20 minutes each hour. When the 5522A is outputting currents between 5 and 11 amps for long periods, the internal self-heating reduces the duty cycle.
  • Page 24 5522A Getting Started Noise Range Bandwidth 0.1 Hz to 10 Hz p-p Bandwidth 10 Hz to 10 kHz rms 0 to 329.999 μA 2 nA 20 nV 0 to 3.29999 mA 20 nA 200 nV 2.0 μA 0 to 32.9999 mA 200 nA 20 μA...
  • Page 25: Resistance

    Multi-Product Calibrator Detailed Specifications Resistance Absolute Uncertainty, tcal ±5 °C ±(ppm of output +floor) Resolution Floor (Ω) Range Allowable Current ppm of output Ω Temp and temp since ohms zero cal 12 hrs ±1 °C 7 days ±5 °C 90 days 1 year 0 to 0.001...
  • Page 26: Ac Voltage (Sine Wave)

    5522A Getting Started AC Voltage (Sine Wave) Absolute Uncertainty, Max Distortion and tcal ±5 °C Noise Range Frequency Resolution 10 Hz to 5 MHz ±(ppm of output + μV) Burden Bandwidth 90 days 1 year ±(% output + floor) Normal Output 1.0 mV to...
  • Page 27 Multi-Product Calibrator Detailed Specifications AC Voltage (Sine Wave) (cont.) Absolute Uncertainty, Max Distortion and tcal ±5 °C Noise Range Frequency ±(% of output + μV) Resolution 10 Hz to 5 MHz Burden Bandwidth 90 days 1 year ±(% output + floor) AUX Output 10 mV to 10 Hz to 20 Hz...
  • Page 28: Ac Current (Sine Wave)

    5522A Getting Started AC Current (Sine Wave) Max Distortion & Absolute Uncertainty, Noise 10 Hz to tcal ±5 °C Compliance 100 kHz BW Inductive Range Frequency ±(% of output + μA) adder ±(μA/V) ±(% of output + Load μH floor)
  • Page 29 T-I minutes any 60 minute period where T is the temperature in °C (room temperature is about 23 °C) and I is the output current in Amps. For example, 17 A, at 23 °C could be provided for 60-17-23 = 20 minutes each hour. When the 5522A is outputting currents between 5 and 11 amps for long periods, the internal self-heating reduces the duty cycle.
  • Page 30: Capacitance

    5522A Getting Started Capacitance Absolute Uncertainty, Allowed Frequency or tcal ±5 °C Charge-Discharge Rate [1] [2] [3] ±(% of output + floor) Range Resolution Min and Max to Typical Max for Typical Max for 90 days 1 year Meet <0.5 % Error <1 % Error...
  • Page 31: Temperature Calibration (Thermocouple)

    Multi-Product Calibrator Detailed Specifications Temperature Calibration (Thermocouple) Absolute Uncertainty Absolute Uncertainty Source/Measure Source/Measure Range Range tcal ±5 °C tcal ±5 °C Type °C Type °C ± °C ± °C 90 days 1 year 90 days 1 year 600 to 800 0.42 0.44 -200 to -100...
  • Page 32: Temperature Calibration (Rtd)

    600 to 630 0.14 0.16 Resolution is 0.003 °C Applies for COMP OFF (to the 5522A Calibrator front panel NORMAL terminals) and 2-wire and 4-wire compensation. Based on MINCO Application Aid No. 18 DC Power Specification Summary Current Range 0.33 to 0.33 to...
  • Page 33: Ac Power (45 Hz To 65 Hz) Specification Summary, Pf=1

    Multi-Product Calibrator Detailed Specifications AC Power (45 Hz to 65 Hz) Specification Summary, PF=1 Current Range 3.3 to 9 to 33 to 90 to 329.99 mA Voltage Range 8.999 mA 32.999 mA 89.99 mA Absolute Uncertainty, tcal ±5 °C, ±(% of watts output) 33 to 329.999 mV 0.13 0.09...
  • Page 34: Phase

    5522A Getting Started Phase 1-Year Absolute Uncertainty, tcal ±5 °C, (Δ Φ °) 10 to 65 to 500 Hz to 1 to 5 to 10 to 65 Hz 500 Hz 1 kHz 5 kHz 10 kHz 30 kHz 0.10 °...
  • Page 35: Additional Specifications

    1 kHz With REF CLK set to ext, the frequency uncertainty of the 5522A is the uncertainty of the external 10 MHz clock ± 5 μ Hz. The amplitude of the 10 MHz external reference clock signal should be between 1 V and 5 V p-p.
  • Page 36: Ac Voltage (Sine Wave) Extended Bandwidth

    5522A Getting Started in this example, the specification is 0.015 % +4 mV as the 0.015 % is the same, and the floor is twice the value (2 x 2 mV). AUX (50th Harmonic) Output: 100 mV, 5 kHz ..........From “AC Voltage (Sine Wave) Specifications” the auxiliary output specification for 100 mV, 5 kHz, is 0.15 % + 450 mV.
  • Page 37: Ac Voltage (Non-Sine Wave)

    Multi-Product Calibrator Additional Specifications AC Voltage (Non-Sine Wave) Frequency Max Voltage Triangle Wave & 1-Year Absolute Uncertainty, tcal ±5 °C, Resolution Truncated Sine Range, p-p ±(% of output + % of range) Normal Channel (Single Output Mode) 0.01 to 10 Hz 5.0 + 0.5 Two digits on each range 10 to 45 Hz...
  • Page 38 5522A Getting Started AC Voltage (Non-Sine Wave) (cont.) 1-Year Absolute Uncertainty, Square Wave Max Voltage Range tcal ±5 °C, Frequency Resolution ±(% of output + % of range) (p-p) Normal Channel (Single Output Mode) 0.01 to 10 Hz 5.0 + 0.5...
  • Page 39: Ac Voltage, Dc Offset

    Multi-Product Calibrator Additional Specifications AC Voltage, DC Offset 1-Year Absolute Uncertainty, Max Peak tcal ±5 °C Range (Normal Channel) Offset Range Signal ±(% dc output + floor) Sine Waves (rms) 0.1 + 33 μV 3.3 to 32.999 mV 0 to 50 mV 80 mV 33 to 329.999 mV 0 to 500 mV...
  • Page 40: Ac Current (Non-Sine Wave)

    5522A Getting Started AC Current (Non-Sine Wave) Triangle Wave & 1-Year Absolute Uncertainty tcal ±5 °C Max Current Truncated Sine Wave Frequency ±(% of output + % of range) Resolution Range p-p 10 to 45 Hz 0.25 + 0.5 0.047 to...
  • Page 41: Ac Current, Square Wave Characteristics (Typical)

    Multi-Product Calibrator Additional Specifications AC Current, Square Wave Characteristics (typical) Range LCOMP Risetime Settling Time Overshoot I <6 A @ 400 Hz 25 μs 40 μs to 1 % of final value <10 % for <1 V Compliance 3 A & 20 A Ranges 100 μs 200 μs to 1 % of final value <10 % for <1 V Compliance...
  • Page 42 5522A Getting Started...

Table of Contents