• InFo Display

Information
INFO
display
8
Serial
(ode
communication
code
9
Software
updt
version
10
ProG
Program number
222
Number of
len
program steps
223
Program type and
p. t y
restart mode
224
Program type and restart mode
0
Restart from first step; the setpoint
copies the value of PV
1
Restart from conditions prior to stop
2
Restart with step search
(see "Programmer Functions")
+ 8 Wait for STOP / START switching
+ 16 Continuous loop; at end of cycle the program restarts
from first step (excludes +32 function)
+ 32 At end of cycle the control output goes to "FAcP"
value, set in "CFG" menu
+64 Fast simulation (see "Programmer Functions")
Select program and step
StEP
to set
226
SP. s
S step setpoint
227
"S" step ramp time (time set
refers to time base selected
rp. t
[HH:MM or MM:SS] - see "SP.
Pr" parameter in
"Hrd" menu)
228
"S" step hold time (time set
So. t
refers to time base selected
[HH:MM or MM:SS)
229
St. y
Defines "S" step type. Hold Back Band (HBB)
function; lets you disable HBB during a segment or
entire step. Parameter is ON if HBB is enabled
230
(see "SP.Pr" parameter on "Hrd" menu)
Sty
HBB enabled
for ramp
0
1
x
2
3
x
4
5
x
6
7
x
+ 8 to enable slave setpoint ramp
Sl. s
Setpoint slaved to step "S",
for second external channel
(to be retransmitted to a slave
231
controller); available if enabled
(see "SP.Pr" parameter on
"Hrd" menu)
80215G_MHW_800P_07-2021_ENG
Software
prot
protection
code
11
Self diagnostic
er. n r
error code
12
0
No Error
1
Lo
2
Hi
3
ERR
4
SBR
• ProG
0 ... 3
1 ... 8
0 ... 127
• StEP
P0-0 ... P3-7
Lo_L ... Hi_L
0.0 ... 99.59
0.0 ... 99.59
HBB enabled
HBB referred to PV
for hold
or auxiliary input
PV
PV
x
PV
x
PV
aux. input
aux. input
x
aux. input
x
aux. input
0.0 ... 100.0%
retransmitted
output value
"S" step ramp
eu. r
events
232
eu. s
"S" step hold
events
233
ipt
Step "S" advanced through digital input function. When
digital inputs have state set in this function, program
automatically advances to next step, otherwise it "waits" at
234
end of previous step (function is enabled through "SP.Pr"
parameter on "Hrd" menu); "d.i.F.1" and/or "d.i.F.2" set to 12.
IPt
0
1
2
3
xbb
Hold Back Band value, symmetrical to active
setpoint. Available if enabled (see "SP.Pr"
parameter on "Hrd" menu); can be disabled during
235
a program segment ( see "Sty" parameter).
Selection of a control
GrP.
parameter group
during ramp phases
242
and holding of setpoint
programmer.
+ 16 to force the power limit of group 0 when in "hold" phase
• C.GrP
Selection of a control
C.GrP
parameter group
to be set.
243
Proportional band for
h pb
heating or hysteresis for
-
ON/OFF control
244
Integral time
h it
-
for heating
245
Derivative time
h dt
-
for heating
246
Maximum power limit
h. P. x i
for heating
247
Minimum power limit for
h. P. L o
heating (not available for
double heat/cool action)
248
Eu.r
or
Event 1
Event 2
Event 3
Event 4
Eu.S
0
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
9
ON
OFF
OFF
10
OFF
ON
OFF
11
ON
ON
OFF
12
OFF
OFF
ON
13
ON
OFF
ON
14
OFF
ON
ON
15
ON
ON
ON
IN1 = ON
IN2 = ON
x
x
x
x
0 ... 999
scale points
GrP.
Ramp
Hold
group
group
0
0
0
1
0
1
2
0
2
3
0
3
4
1
0
5
1
1
6
1
2
7
1
3
8
2
0
9
2
1
10
2
2
11
2
3
12
3
0
13
3
1
14
3
2
15
3
3
0 ... 3
0.0 ... 999.9%
full scale
0.00 ... 99.99 min
0.00 ... 99.99 min
0.0 ... 100.0%
0.0 ... 100.0%
ON
ON
ON
ON
ON
ON
ON
ON
21