A - Programming; Menu Display Modes; Programming Of "Function Block" Analog And Digital Input Signals; Variable Interconnections Mode - gefran SIEIDrive ADV100 Functions Description And Parameters List

Field oriented vector
Hide thumbs Also See for SIEIDrive ADV100:
Table of Contents

Advertisement

A – Programming
A.1 Menu display modes
The programming menu can be displayed in two modes, which can be selected using the Access mode parameter
(04 - DRIVE CONFIG menu):
• Easy (default)
• Expert
A.2 Programming of "function block" analog and digital input signals
The signals, variables and parameters of each single "function block" of the drive are interconnected in order to
achieve the configurations and controls inside the control system.
These can be managed and modified using the keypad, PC configurator or fieldbus programming.
The programming mode is based on the following logic:
Src
cfg
mon
Input selected
src
A.3 Variable interconnections mode
The source (src) allows the desired control signal to be assigned to the function block input.
This operation is performed by using specific selection lists.
Possible control signal sources:
1 – Physical terminal
The analog and digital signals come from the terminal strip of the regulation card and/or from those of the expansion
cards.
2 – Drive internal variables
Internal drive control system variables, from "function block" calculations, sent via keypad, PC configurator or field-
bus.
ADV100 • Functions description and parameters list
only the main parameters are displayed.
all the parameters are displayed
(source; i.e.: Ramp ref 1 src, PAR: 610)
This term defines the source of the function block input, i.e. the signal to be processed in the
function block.
The different configurations are defined in the relative selection lists.
(configuration; i.e.: Mpot init cfg, PAR: 880)
This term refers to the parameter setting and its effect on the function block.
For example: Ramp times, internal reference adjustment, etc...
(display; i.e.: Ramp ref 1 mon, PAR: 620)
This term refers to the variable output from the function block, which is the result of the
calculations performed on the actual block.