• Do not replace the Teflon when the bar is still hot, due to the risk of burns.
• Always unplug the appliance before carrying out any maintenance.

15.1 Replacement of complete sealing bar

• Extract the sealing bar from the vacuum chamber by lifting it horizontally from the sides (Fig. 1).
• Insert the new one, making sure the bar is properly engaged with the electrical contacts
Fig. 1
15.2 Replacement of sealing bar Teflon cover
• Extract the sealing bar from the vacuum chamber by lifting it horizontally from the sides.
• Unscrew the screws used to secure the sealing bar to the support (Fig. 2).
• Detach the bar from its support (Fig. 3).
evox
31
Rev. 02 - 06/2018 - Cod. 1500339 - Vacuum packaging machine user manual
Hi-Line

15. MAINTENANCE

Fig. 2
.
A
A
MAINTENANCE
Fig. 3