13 Pump OIL DATA

WARNING!
It is important for the pump oil (specific for food vacuum applications and FDA certified) to
always be kept in optimal conditions: fluid and clean, i.e. free from grit and watery parts.
Check the oil level periodically: if the vacuum machine is used in catering or restaurant sector, the pump
dehumidification cycle must be performed daily, at the end of working day. In other cases, it must be
performed at least weekly
1) The oil must be changed according to the workload, in any case every 6 months, or once the number of
cycles programmed has been reached and on the machine display appears OIL.
Contact the service center to perform the oil change.
At every oil change, replace the exhaust filter, too.
2) It is necessary to change oil before an inactivity time longer than two months.
residues and liquids, remained in the oil tank during the inactivity time, will be drained together with the
exhaust oil.
3) The room temperature should not fall below than +10°C, to avoid the pump oil
facilitates the starting of cold pump.

14 scheduled routine maintenance

Implementing the scheduled maintenance regularly, as described further on in this manual, minimises
and/or eliminates potential faults and interference and increases the machine lifetime
Failure to perform regular maintenance can lead to significant repair costs, and in certain cases, render the
guarantee null and
void. Furthermore, respecting the recommendation, a good hygienic level is
guaranteed.
To carry out cleaning and routine maintenance operations safely, follow the regulations listed below:
ELECTRICAL HAZARD! If the power supply cable is damaged, it must be replaced.
ELECTRICAL HAZARD! The power sources must be disconnected before cleaning, disinfecting,
performing maintenance and/or repairing any component of the appliance (Disconnect the
electrical plug from the mains).
DANGER! It is strictly prohibited to remove the guards and safety devices to perform routine
maintenance. Orved S.p.A. declines all liability for accidents due to non-compliance with
the above-mentioned obligation.
WARNING!
Always use suitable preventive measures and protective devices (gloves, etc.) for any
maintenance, handling, installation and cleaning operations.
WARNING! Only qualified technicians must perform maintenance or access live parts of the
machine.
Contact a Technical Support C entre authorised by the manufacturer for any repairs. Only original
spare parts must be used and requested.
Do not perform maintenance yourself where the intervention of a qualified technician is indicated
in the manual.
Do not touch the machine with bare, damp or wet hands or feet.
Do not insert screwdrivers, kitchen instruments or anything similar between the guards, openings
and moving parts of the machine,
After completing the work, detach the piston by pushing it toward the rear and lower the lid to
the resting position. This protects the vacuum chamber from dust and dirt.
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
Doing so, all oxidized
thickening. Better oil fluidity
significantly.
IDEA
vacuum packing machines
Pag. 56 a 76
MACHINE PART
INTERVENTION
Check the oil level and colour;
top-up if necessary or replace, if
Pump
the colour is too dark or whitish
(contact a specialised service
centre).
Operate a pump heating cycle
Pump
for at least 5 minutes, or a pump
dehumidification cycle.
Verify its integrity; replace
Power cord
if defective
Verify its integrity; if there are any
cracks or streaks, contact the
Plexiglass lid
after-sales centre to
replace the lid.
Upper bar
Check that they are inserted well
silicone and
into the respective seats; replace
Plexiglass lid
if defective or worn.
gasket
Machine and
vacuum
Clean impurities, oil and grease.
chamber
Sealing bar
Check that it is inserted well on
connection
to the two contact pins.
Run a pump dehumidification
Pump
cycle.
Clean the upper part with a
Sealing bar
damp cloth.
Clean the two contact pins.
Machine,
vacuum
Sanitize
chamber, lid
and fillers.
Pump
Replace the pump oil
Pump
Replace the oil filter
Change the oil and replace the
Pump
oil filter before a long inactivity
(time longer than 2 months)

15 TROUBLESHOOTING

ERRORE
PROBLEM
1
Machine not working.
Insufficient vacuum in the
2
bag/bag does not maintain
vacuum.
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
FREQUENCY
INTERVENTION PERFORMED
1-G
1-S
6-M
1-A
4-A
USER
X
O
X
O
X
O
X
O
X
O
X
O
X
O
X
X
O
X
O
X
O
X
X
The present intervention has
to be performed before a
long inactivity period
POSSIBLE CAUSES
SOLUTION
Switch the machine on (press
Machine off
STOP button for 5")
 Insert the plug in a socket
(check the voltage!).
• Check power cable to make
sure it is intact.
No power supply
• Check fuse PF1 on the
power board to make sure
they are intact and inserted
correctly (contact a service
centre).
Machine damage
Contact the authorised
service center
Place the bag centrally on
Bag Incorrectly positioned
the sealing bar overpassing it
about 20 mm.
Choose a thicker bag and
Bag perforated
wrap the product
with cling film or soft paper.
Insufficient sealing
Increase the sealing time
IDEA
vacuum packing machines
SERVICE
CENTER
Oil top-up or
replacement.
Replacement
Replacement
Replacement
O
O
O
Pag. 57 a 76

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idea 40Idea 31Idea 41Idea 32 hi-lineIdea 42 hi-line

Table of Contents