Maintenance; General Warnings; Programmed Maintenance; Care And Cleaning Of The Vacuum Packaging Machines - Orved CUISSON VMOSV31 Operating And Service Manual

Table of Contents

Advertisement

EN

MAINTENANCE

7.
MAINTENANCE
7.1

GENERAL WARNINGS

ELECTRIC HAZARD!
Maintenance and/or repair operations on any of the appliance components must be done only after disconnecting the power
supplies (Disconnecting the plug from the mains).
CAUTION!
Only qualified personnel must be allowed to carry out maintenance operations or access powered parts of the machine.
ELECTRIC HAZARD!
Disconnect the electric current before carrying out cleaning or maintenance.
For repairs, if necessary, contact a Service Centre authorized by the manufacturer. Use and demand genuine spare parts.
7.2

PROGRAMMED MAINTENANCE

FREQUENCY
Before each start up
Weekly
Every 12,500 operating cy-
cles (approx. 50 hours for
Mod. SV-31).
Every 20,000 operating cy-
cles (approx. 100 hours for
Mod. SV-41).
Every two oil changes
Every 6 months
7.3
CARE AND CLEANING OF THE VACUUM PACKAGING MACHINE
ELECTRIC HAZARD!
Danger of electric shock ! Remove the machine plug from
the power socket. Do not use water or steam jets.
DANGER! Danger of burns: if alcohol-based or inflammable
EN
disinfectant products are used, ventilate the area. Do not use
naked flames near the machine! Do not smoke!
CAUTION! Danger of injury! Use personal protective
equipment. Do not use caustic products, acids or aggres-
sive products such as muriatic acid. Read the instructions
on the detergent product or disinfectant pack carefully.
WARNINGS! Use alcohol-based disinfectants.
The machine must be cleaned and disinfected every time
after use.
Operation and maintenance manual / Ed. 11 - 2008
MACHINE PART
Pump
Power cable
Plexiglas cover
Red silicone
and Plexiglas cover gasket
Machine and vacuum chamber
Sealing bar
Pump
Pump
Pump
Pump
CUISSON SV-31 • SV-41
Check the oil colour and level; top up the level,
or change it completely if the colour is dark or
whitish.
Check to make sure it is intact, replace if
damaged (Contact a specialist Service Centre).
Check to make sure it is intact ; if cracks or
streaks are present, contact Customer service
for replacement.
Check to make sure they are inserted properly
in their seats; replace if damaged.
Clean to remove impurities, oil and grease.
Clean the upper part with a damp cloth.
Run the pump for about 30 minutes (using the
Pump function) to allow removal of water from
the pump oil.
Change the pump oil
(call a specialist Service Centre).
Change the pump exhaust filter (A)
(call a specialist Service Centre).
Change the pump oil.
(call a specialist Service Centre).
48
ACTION
A
REV. 01 - Cod.: 1500288

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cuisson sv-31Cuisson sv-41

Table of Contents