Bosch Rexroth IndraMotion MLD Series Applications Manual page 138

Table of Contents

Advertisement

136/267
Bosch Rexroth AG
Visualization and engineering interfaces
Setting IP address, network mask
and default gateway via standard
control panel
Setting IP address, network mask
and default gateway via
IndraWorks
IP address, network mask and default gateway can be parameterized via the
control panel at the drive controller; this is only possible in parameter mode. It
might possibly be necessary to switch to the parameter mode via the control
panel; the paragraph below describes how to do this.
1.
Switch on the control voltage of the drive controller.
2.
Simultaneously press the "ESC" and "Enter" keys on the control panel
for approx. 8 seconds.
3.
Use the "Up"/"Down" arrow keys to select "2. Comand" and confirm the
selection with the "Enter" key.
4.
If you have to switch to parameter mode, use the "Up"/"Down" arrow
keys now to select "2.11 > PM" and start the command with the "Enter"
key.
5.
Now select "2.3 Kom. Ethernet" and confirm the selection with the
"Enter" key.
6.
The IP address can now be set under "2.3.1 P-0-1531".
The individual octets (bytes) are applied by pressing the "Enter"
key. This procedure can be aborted with "Esc".
7.
The network mask can be set under "2.3.2 P-0-1532".
8.
The default gateway can be set under "2.3.3 P-0-1533".
In order that the parameter setting of desired IP address, network
mask and default gateway takes effect, the control voltage of the
drive controller must be switched off and on again.
IP address, network mask and default gateway can be parameterized via
IndraWorks MLD.
1.
Start IndraWorks MLD; when starting, select "IndraDrive (Ethernet)" as
connection type.
2.
In IndraWorks MLD open the tree in the project explorer window.
3.
Right-click on "IndraDrive" (hardware level) in the project explorer win‐
dow and open "Sercos III" in the drop-down menu.
The "Sercos III" tab opens in the work area.
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth indramotion mld-sRexroth indramotion mld-m

Table of Contents