Isg2 Hardware Settings - General DataComm Xedge 6000 Series Hardware Installation

Table of Contents

Advertisement

V7.x Packet Controllers

ISG2 Hardware Settings

S1
Figure 4-1
Table 4-1
ISG2 Controls and Indicators
Items
Designation Description
Front Panel
FLT LED
Status LEDs
RUN LED
LNK FLT
Front Panel
MGMT
Ports
USER
On-board
P3
Jumper
On-board
S1
Rotary Switch
(See
(16-position)
Figure
4-2)
Note
IMPORTANT ! Be aware that when S1 is set to F, all user configuration files and XOS code will be erased
from the card. This setting should be used with caution, and you must reset S1 back to 0, 4 or 8 immediately
after reboot to prevent inadvertent erasure with subsequent reboots.
Note
Additional S1 settings can be used to reboot the card to kernel for troubleshooting purposes, under the
guidance of your authorized Xedge field service representative.
4-4
To Switch
Fabric
3
P3
1
ISG2 Base Card
ISG2 Front Panel
ISG2 Card Layout
FLT (red) is normally off; Lit when a problem prevents the Slot Controller from functioning.
RUN (green) illuminates when the Slot Controller is powered on and operating.
LNK FLT (red) is not supported in this release.
10/100 8-pin modular jack connects to Prosphere Server or ProSphere Server network.
10/100 8-pin modular jack connects to Ethernet network.
Only for use in factory tests. For normal operation, this jumper must be set to
Pins 2 and 3, as shown above.
Set to 0 when ISG2 is in Main Slot 0 of any Xedge 6000 chassis.
Set to 4 when ISG2 is in Standby Slot 0 of Xedge 6280, 6640 or 6645 chassis.
Set to 8 when ISG2 is in Non-slot 0 of any Xedge chassis (slot 0 must be PCx or ISG2).
Set to F to delete all user-defined configuration files and XOS code (i.e. to factory default).
Xedge 6000 Hardware
Installation & Setup Guide
ISG2 Controller Overview
BACKPLANE
CONNECTORS
To
Backplane
032R440-000
Issue 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xedge 6280Xedge 6160Xedge 6645Xedge 6002Xedge 6640

Table of Contents