Lce-16 Lim Overview - General DataComm Xedge 6000 Series Hardware Installation

Table of Contents

Advertisement

Line Interface Modules

LCE-16 LIM Overview

The LCE-16 LIM can be used with a variety of controllers listed in
16-port circuit emulation LIM sends ATM cells to the controller.
Front Panel Indicators
IS (In Service) GREEN LED ON indicates all the enabled links are in the up
state, or no link is enabled. LED OFF indicates an operational problem; LIM may
require a restart. LED blinking indicates at least one link is in a diagnostics state.
AL (Alarm) RED LED ON indicates a fault on at least one enabled link.
LED OFF indicates none of the enabled links has a fault condition.
IS and AL blinking indicates lost communication between LIM and controller.
Front Panel Connectors
LINK 0-7 is the 100-pin high density connector for transmit/receive signals.
LINK 8-15 is the 100-pin high density connector for transmit/receive signals.
Front Panel Jumper
There are no user-selectable jumpers on the LCE-16 LIM. The X1 jumper shown
below for reference purposes, is for factory use only. The Normal store position
(Pins 1 and 2) is for storing the jumper. Removing the jumper from this position has
no effect on LIM operation.
Figure 5-18
5-32
Boot Jum per
For Factory Use O nly
1
2
3
X1
Load Softw are
Jum p P ins 2 & 3
Normal (store)
Jum p P ins 1 & 2
(norm al show n)
LCE-16 LIM Front Panel Features and Jumper Location
Xedge 6000 Hardware
Installation & Setup Guide
LCE-16 LIM Overview
Table
1-4. This
LCE-16
LINK 0-7
AL IS
LINK 8-15
032R440-000
Issue 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xedge 6280Xedge 6160Xedge 6645Xedge 6002Xedge 6640

Table of Contents