Slot Controller Setup; Front Panel Indicators - General DataComm Xedge 6000 Series Hardware Installation

Table of Contents

Advertisement

Switch Fabric and V6.2 Controllers

Slot Controller Setup

The following describes the front panel and onboard features of the ACP,
ACS, ECC, ETH, VSM, CE, CHFRC and FRC controllers. Indicators
and jumpers operate in the same manner except where noted. The ACP,
ACS, VSM, ECC controllers have no user-selectable jumpers.

Front Panel Indicators

For ECC Controller Only
LINK FAULT Indicator (ECC only)
Illuminates red when a fault condition exists on one of the associated
LIM link.
FLT Indicator
Illuminates red when a problem prevents the controller from
functioning. Normally off.
RUN Indicator
Illuminates while the controller is powered on and operating.
For ACP, ACS, ETH, VSM, CE, CHFRC and FRC Controllers:
FLT Indicator
Illuminates red when a problem prevents the controller from
functioning. Normally off.
RUN Indicator
Illuminates while the controller is powered on and operating.
Link Indicators (Link 1, Link 2, Link 3)
Four groups of Link indicators illuminate as described below.
Link 2 and Link 3 indicators are inactive when the controller is
installed with a two-channel LIM.
RX Indicator
Flashes yellow when the link is receiving data.
UP Indicator
Illuminates green while the link is functional.
TX Indicator
Flashes yellow when the link is transmitting data.
ER Indicator (Normally off)
ER on while UP is on indicates detection of a line defect.
ER on with UP off indicates a line alarm condition.
ER flashing indicates a LIM fault.
Figure 3-1
Note
Instead of RX, UP, TX and ER indicators for each link, the ECC Slot Controller has one
indicator for all links.
3-4
Typical Slot Controller Front Panels (Shown: ACP and ECC)
Xedge 6000 Hardware
Installation & Setup Guide
Slot Controller Setup
ACS
ECC
FLT
FLT
RUN
RUN
LINK 0
LINK
FLT
RX
UP
TX
ERR
LINK 1
RX
UP
TX
ERR
LINK 2
RX
UP
TX
ERR
LINK 3
RX
UP
TX
ERR
LINK FAULT