Line Interface Modules

Class A EMI-RFI Suppression Requirements

With the DS3-2C, E3-2C and 155E-2 LIMs, be sure to comply with all domestic and international
Class A EMI-RFI suppression requirements by installing the proper ferrite beads on the TX and RX
cables, as shown in the figures below. Note that ferrite bead type and placement varies depending
on the Xedge chassis in use.
Note
IMPORTANT! The TX and RX cables must use the Belden Coaxial Cable, P/N 9054 or equivalent. Slot/LIM
applications in the Xedge 6002 may require additional ferrite beads. Consult your Xedge representative.
Xedge 6640, 6645, 6280 and 6160 Chassis Only
LIM Front Panel
(side view)
Figure 5-25
Xedge 6002 1RU Chassis Only
Xedge Chassis
A
Front Panel
5" max
looped cable
Ferrite bead
P/N 232-008-015
Figure 5-26
032R440-000
Issue 17
Belden Coax cable
P/N 9054 (or equivalent)
5" max
LIM Class A EMI-RFI Suppression in Xedge High Density Chassis
Xedge 6002 Chassis
(Shown with Xedge PCX Slot Controller)
B
B,C
5" max
LIM Class A EMI-RFI Suppression in the Xedge 6002 Chassis
Xedge 6000 Hardware
Installation & Setup Guide
Class A EMI-RFI Suppression Requirements
Ferrite bead
P/N 232-005-004
(3 for each TX/RX port)
D
C
D
Slot Controller
Front Panel
cable
5" max
Ferrite bead
P/N 232-008-014
(1 for each port)
A
DS3, E3 or 155E LIM
Front Panel
Belden
coax cable (2)
Ferrite bead
P/N 232-005-004
(3 for each TX/RX port)
5-43