General DataComm Xedge 6000 Series Hardware Installation page 143

Table of Contents

Advertisement

Line Interface Modules
Optional 120 Ohm E1 Distribution Panel Kit
The optional 120 Ohm E1 Distribution Panel Kit (032M164-001) is used with the E1 IMA/IMA+
LIMs only and contains the following components:
Two 120 Ohm, 25-Twisted Pair, Shielded Cables (025H602-006)
One RJ48M to RJ48C Distribution Panel (S-032A011-002xx)
E1-IMA LIM
(not supplied)
RX (in)
TX (out)
chassis
ground
= Twisted Pair
= Connection
TX = Transmit
RX = Receive
Figure 5-23
Note
Distribution panel pinouts are described in
032R440-000
Issue 17
120 Ohm
25-Twisted Pair
Shielded Cable
025H602-006
1-Ring
1-Ring
26-Tip
26-Tip
3
2-Ring
2-Ring
27-Tip
27-Tip
28
shield
50-pin Telco
connectors
Connection Diagram, 120 Ohm E1 Distribution Panel Kit (one link shown)
Table
Xedge 6000 Hardware
Installation & Setup Guide
DSX-1 and E1 IMA/IMA+ LIM Overview
E1 Distribution Panel
S-032A011-002xx
RX
3
RX shield
TX
28
TX shield
chassis
ground
5-5.
120 Ohm
4-Twisted Pair
Shielded Cable
(not supplied)
1, 2
1, 2
3
3
4, 5
4, 5
6
6
shield
RJ45
connectors
5-41