Xedge Chassis Systems

Xedge 6160 Chassis

Xedge 6160 is a compact, standalone 5-slot chassis available in AC and DC power versions.
The AC-version of the chassis uses autoranging power supplies that automatically adapt to AC
power inputs ranging from 90 to 264VAC. For detailed specifications, refer to the table below.
The Xedge 6160 chassis is shipped from the factory with a door covering the front panel. In cabinet/
rack-mount installations, the door may be removed if it interferes with equipment installed below
the chassis.

Xedge 6160 Technical Specifications

Table 2-5
Xedge 6160 Chassis Specifications
Xedge 6160 AC Version (P/N 010B203-001), GPS-16A AC Power Supply (P/N 035B011-002)
Input Voltage Range
Input Frequency
Maximum Power Consumption
Service Current Requirement
Fuse Rating
Heat Dissipation
Xedge 6160 DC Version (P/N 010B204-001), DPS-16A DC Power Supply (P/N 041B011-001)
Input Voltage Range
Maximum Power Consumption
Fuse Rating
Heat Dissipation
Dimension (H x W x D):
Temperature, operating
Temperature, non-operating
Humidity
Altitude, operating
Altitude, non-operating
Compliance

Module Installation

Refer to Chapter 3, Switch Fabric and V6.2 Controllers for procedures on how to properly install
and remove modules in and out of the Xedge 6160 chassis.
Note
IMPORTANT! To avoid equipment damage, install only supported Xedge modules in appropriate slots of the
Xedge 6160 chassis. Refer to
032R440-000
Issue 17
90 to 264 VAC
50 to 60 Hz
350 W (with one power supply)
15A
6.3A, 250 VAC, each power supply
1,195 BTU/hr, maximum
-42 to -70 VDC
350 W (with one power supply)
10A, 250 VDC, each power supply
1,195 BTU/hr, maximum
Xedge 6160 AC and DC Units
4.38 in (11.1 cm) x 17.5 in (44.4 cm) x 19.0 in (48.3 cm)
32 to 122 deg. F (0 to 50 deg. C)
-40 to 158 deg. F (-40 to70 deg. C)
Up to 95% without condensation
0 to 10,000 ft (0 to 3,047 m)
0 to 40,000 ft (0 to 12,191 m)
CISPR 22 Class A
UL Listed (UL1950)
c-UL Listed (CSA C22.2 #950)
TUV licensed (EN60950)
CE Mark