Switch Fabric Setup; Front Panel Indicators - General DataComm Xedge 6000 Series Hardware Installation

Table of Contents

Advertisement

Switch Fabric and V6.2 Controllers

Switch Fabric Setup

The following describes the front panel and onboard features of the
Xedge Switch Fabric modules: XH, XS and XM. Indicators and jumpers
operate in the same manner except where noted.

Front Panel Indicators

All Xedge switch fabric modules have front panel TX and RX LEDs that
correspond to each slot controller interface. The XH, XS and XM have
LEDs for 16 interfaces (S0 - S15). The front panel LEDs on the XM and
can be set to one of three display modes by setting an onboard jumper.
FLT Indicator
Illuminates red when a problem prevents the Switch Fabric from
functioning. Normally Off.
RUN Indicator
Steady On while the Swtich Fabric is powered on and operating.
Normally On. (See Redundant Fabric, below)
TX Indicator
Illuminates when data is sent from the associated slot controller to the
Switch Fabric.
RX Indicator
Illuminates when data is received at the associated slot controller
from another controller in the switch.
Health Checks
Once every second, the Slot-0 Controller sends a health check request
cell to all active controllers in the switch via the Switch Fabric module.
Each active controller responds to the Slot-0 Controller with a health
check response cell via the Switch Fabric module.
This health check request/response sequence causes the TX and RX
LEDs on the Switch Fabric module to blink once every second for each
active Slot Controller.
Redundant Switch Fabric
The XH or XM Switch Fabric modules can be installed as Main or
Standby fabric in a redundant system. When in-service, the RUN LED
is steady On. When out-of-service, the RUN LED flashes.
Figure 3-3
Note
IMPORTANT! In a redundant system, always put the Switch Fabric in Standby mode (out-of-service) before
hot-swapping the module. The out-of-service Switch Fabric module can then be removed without interrupting
communication in the switch.
3-8
Switch Fabric Modules
Xedge 6000 Hardware
Installation & Setup Guide
Switch Fabric Setup
XH
XS
XM
FLT
FLT
FLT
RUN
RUN
RUN
TX
RX
TX
RX
TX
RX
S0
S0
S0
S1
S1
S1
S2
S2
S2
S3
S3
S3
TX
RX
TX
RX
TX
RX
S0
S0
S0
S1
S1
S1
S2
S2
S2
S3
S3
S3
TX
RX
TX
RX
TX
RX
S8
S8
S8
S9
S9
S9
S10
S10
S10
S11
S11
S11
TX
RX
TX
RX
TX
RX
S12
S12
S12
S13
S13
S13
S14
S14
S14
S15
S15
S15
032R440-000
Issue 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xedge 6280Xedge 6160Xedge 6645Xedge 6002Xedge 6640

Table of Contents