General DataComm Xedge 6000 Series Hardware Installation page 58

Table of Contents

Advertisement

Xedge Chassis Systems
Table 2-8
Xedge 6645 Chassis Technical Specifications
Xedge 6645 DC Chassis (P/N 010B198-001), DPS-14 DC Power Supply (041P114-001)
Input Voltage (Nominal)
Input Current
Maximum Consumption
Fuse Rating
Service Current Requirement
Heat Dissipation
Dimensions (H x W x D)
Weight
Temperature, operating
Temperature, non-operating
Humidity
Altitude, operating
Altitude, non-operating
Compliance
2-28
-48 VDC nominal, (-42 to -70 VDC)
27A at -48 VDC
1300 W (with two power supplies)
20A / 250V
35A
4,600 BTU/hr maximum
24.5 in (62.2 cm) x 19.0 in (48.3 cm) x 16.6 in (42.2 cm)
130 lbs (59 kg), fully loaded
32 to 122 deg. F (0 to 50 deg. C)
-40 to 158 deg. F (-40 to 70 deg. C)
Up to 95% without condensation
0 to 10,000 ft (0 to 3,047 m)
0 to 40,000 ft (0 to 12,191 m)
CISPR 22 Class A
UL recognized (UL1459)
c-UL recognized (CSA C22.2 #225)
TUV licensed (EN60950)
CE Mark
Xedge 6000 Hardware
Installation & Setup Guide
Xedge 6640/6645 Chassis
032R440-000