Ds3-2C Overview - General DataComm Xedge 6000 Series Hardware Installation

Table of Contents

Advertisement

Line Interface Modules

DS3-2C Overview

The DS3-2C LIM is a two port DS3 LIM for ATM transport that can be used with
a variety of controllers listed in
Front Panel indicators
IS illuminates when link is in-service.
OS illuminates when link is out of service. Glows dimly when the LIM is in a
not communicating correctly with the Slot Controller.
LB illuminates during line loopback tests.
RD illuminates when there is a receive (red) loss of frame alarm or loss of
signal.
BL illuminates when there is a receive blue alarm indication signal (AIS)
alarm.
LS illuminates when there is a receive loss of signal alarm.
YL illuminates when there is a receive yellow alarm (FERF- Far End Receive
Failure).
ER illuminates when there is an error on the link receive line. (A parity error
is an example of an error that causes ER to light.)
Front Panel Connectors
• The DS3-2C LIM uses one 75-ohm coaxial cable each for transmit and receive,
following
LINK 0 TX is a 75-ohm BNC connector for the link 0 transmit line.
LINK 0 RX is a 75-ohm BNC connector for the link 0 receive line.
LINK 1 TX is a 75-ohm BNC connector for the link 1 transmit line.
LINK 1 RX is a 75-ohm BNC connector for the link 1 receive line.
IMPORTANT! Refer to
(Figure
5-25) to comply with all domestic and international standards.
Figure 5-8
032R440-000
Issue 17
Table
1-4.
law. (Insertion loss per ANSI T1.102, Figure-9.)
F
Class A EMI-RFI Suppression Requirements
DS3-2C LIM Front Panel Features
Xedge 6000 Hardware
Installation & Setup Guide
DS3-2C Overview
DS3-2C
LINK 0
TX
RX
L0
L1
IS
OS
LB
RD
BL
LS
YL
ER
TX
RX
LINK 1
5-15