Network Timing Modules

DS1 Node Timing Module (NTM-DS1)

Front Panel Indicators
RUN LED Flashing Green indicates that the NTM is starting up and loading
required files.
LED ON Green indicates that the NTM start-up is complete, all required files are
loaded, and the NTM is active in the system.
FLT (Fault) LED ON Red continuously during start-up is normal.
LED ON Red continuously after start-up indicates that the NTM has failed.
TX RC/DR (Transmitting Received Clock/Derived Clock)
LED ON Green indicates that the NTM has been initialized, is configured, and is
transmitting properly.
TA RC (Transmitting AIS Received Clock)
LED ON Red indicates that the NTM is transmitting an alarm indication signal
because it is initializing and/or waiting for its configuration from the Slot-0
Controller.
TA DR (Transmitting AIS Derived Clock)
LED ON Red indicates that the NTM is transmitting an alarm indication signal
because it is initializing and/or waiting for its configuration from the Slot-0
Controller. It may also indicate that both line reference clocks have failed.
RA RC/DR (Receiving AIS Received Clock/Derived Clock)
LED ON Red indicates that the NTM is receiving an alarm indication signal.
LS RC/DR (Receiving LOS Received Clock/Derived Clock)
LED ON Red indicates that the NTM is detecting a loss of signal alarm condition.
OF (RC/DR) Receiving OOF (Received Clock/Derived Clock)
LED ON Red indicates that the NTM is detecting an out of frame alarm condition.
ER (RC/DR) Receiving BER (Received Clock/Derived Clock)
LED ON Red indicates that the NTM is detecting a bit error rate alarm condition.
LOCK (Locked) LED ON Yellow indicates that the NTM oscillator is locked to
the selected reference timing source.
PRI (Primary) LED ON Yellow indicates that the NTM has been configured as
the primary transmit reference timing source of the node.
Front Panel Connectors
RC-IN is a DB-15 female connector that accepts BITS signals from an external
clock system.
DR-OUT is a DB-15 female connector that sends derived BITS signals to an
external clock system.
Figure 6-1
Note
Table 6-1
describes the pinout designations for each of the NTM-E1 connectors.
6-2
NTM-DS1 Front Panel Features
Xedge 6000 Hardware
Installation & Setup Guide
DS1 Node Timing Module (NTM-DS1)
NTM-T1
RC IN
RUN
FLT
RC
DR
TX
TA
RA
LS
OF
ER
LOCK
PRI
DR OUT
032R440-000
Issue 17