T1/E1 Hdcc Lim; Hardware Setup - General DataComm Xedge 6000 Series Hardware Installation

Table of Contents

Advertisement

Line Interface Modules

T1/E1 HDCC LIM

The T1/E1 High Density Cross Connect LIM is a 28 or 32-port LIM intended for use
with the PCx-2 slot controller for aggregation of T1, E1, OC-3, OC-12, E3 and DS3
circuits across a packet network. It supports the following rates:
T1 data rates up to 1.544 Mbps
E1 data rates up to 2.048 Mbps
DS3 data rates up to 44.736 Mbps
OC3 rates up to 599.03 Mbps
Front Panel Features
The front panel connectors provide easy access to the ports. The front panel LEDs
indicate LIM communication status. All LEDs are controlled by the slot controller
software:
RUN LED illuminates when the link is in-service.
ALARM LED illuminates during loopback tests; Blinks when the link
hardware detects an out-of-frame error on the receive line.
Front Panel Connectors
LINK 0-15 and LINK 16-31 are female 68-pin amplimite connectors for
attaching external communication devices to links 0 through 31.
Table 5-4
and lists the pinouts.
An optional 16-port (RJ48) T1/E1 Distribution Panel (S-032A011-002xx) can be
used with the above cable.

Hardware Setup

Jumpers
Jumpers on the T1/E1 HDCC LIM are for factory use only.
Installation
The T1/E1 HDCC LIM occupies a rear panel slot of the switch that is associated with
the corresponding controller. When handling LIMs, always use an antistatic wrist
strap to prevent static discharge damage to the electronic circuits.
1. Install the LIM into an empty slot at the back panel of the chassis.
2. Insert the edges of the module into the tracks of the slot and slide the module
inward until it stops. (LIMs are "hot-swappable".)
3. Connect the appropriate I/O line(s) to the LIM's front panel input connectors
using the proper cables.
4. Refer to the Xedge Configuration Guide to properly configure the LIM for your
application.
Figure 5-7
5-14
shows the 68-pin male to dual 50-pin RJ48 male cable (027H703-008)
Table 5-5
T1/E1 HDCC LIM Front Panel Features
Xedge 6000 Hardware
Installation & Setup Guide
shows panel pinouts.
T1/E1 HDCC LIM
T1/E1
HDCC
LINK 16-31
032R440-000
Issue 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xedge 6280Xedge 6160Xedge 6645Xedge 6002Xedge 6640