9.6.1

AS-I CIRCUIT (Selecting the AS-i circuit)

Main Menu || DIAGNOSIS || SAFETY SLAVES || AS-I CIRCUIT ||
Please select the required AS-i circuit using the arrow buttons and the OK button.
Than you get the diagnostic menu.
9.6.2

SAFETY SLAVES (safety oriented slaves)

Main Menu|| DIAGNOSIS || SAFETY SLAVES || SAFETY ORIENTED SLAVES ||
The list of "Safety Input Slaves" ("AS-i Safety at Work") shows the slaves for
which the safety function has been released.
The grafical symbols indicate the state of the contacts:
The first place corresponds to Channel 2, the second place to Channel 1. Thus
RX means that Channel 2 released and Channel 1 is OK.
The channels can not be evaluated individually, if the substitution of safety slaves
input data was disabled in menu:
• command interface/ function profile
or
• slave value substitute (SAFETY SUBST VALUE).
In this case both channels must have the same state, otherwise the indication will
not be proper.
84
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91
AS-i 3.0 EtherNet/IP Gateway with integrated Safety Monitor
AS-i CIRCUIT 1
AS-i CIRCUIT 2
SAFETY ORIENTED
SLAVES
2-XR
4-
X: The channel is closed
R: The channel is open
Operation in advanced display mode
| 1-XX
| 3-RR
| 5-
© Pepperl+Fuchs, Printed in Germany