Summary of Contents for Pepperl+Fuchs OHV-F230-B17

  • Page 1 FACTORY AUTOMATION MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld...
  • Page 2 OHV-F230-B17 With regard to the supply of products, the current issue of the following document is ap- plicable: The General Terms of Delivery for Products and Services of the Electrical Indus- try, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the...
  • Page 3: Table Of Contents

    OHV-F230-B17 Introduction................. 4 Content of this Document ..............4 Target Group, Personnel..............4 Symbols Used ..................5 Product Specifications............... 6 Description ................... 6 Dimensions................... 6 Indicators ....................6 Interfaces ....................7 Accessories ..................7 Commissioning................8 Operation and Communication ..........9 Communication via PROFINET ............
  • Page 4: Introduction

    OHV-F230-B17 Introduction Introduction Content of this Document This document contains information required to use the product in the relevant phases of the product life cycle. This may include the following: Product identification Delivery, transport, and storage Assembly and installation Commissioning and operation...
  • Page 5: Symbols Used

    OHV-F230-B17 Introduction Symbols Used This document contains symbols for the identification of warning messages and of informative messages. Warning Messages You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid property damage.
  • Page 6: Product Specifications

    Product Specifications Description The OHV-F230-B17 is a gateway that enables OHV100 and OHV1000 handheld readers to be connected to a PROFINET network. An OHV handheld reader is connected to the gateway via an RS-232 connection. The gateway communicates with a PROFINET network via a D-coded M12 connector.
  • Page 7: Interfaces

    OHV-F230-B17 Product Specifications Interfaces The following interfaces are available on the OHV-F230-B17 gateway: RS485 RS232 Figure 2.2 Interface Description Connection RS-232 RS-232, EIA/TIA-232E M12 socket, 8 pin, A-coded Transfer rate: 115 k, 8N1 RS-485 No function M12 socket, 8 pin, A-coded PROFINET 2 x PROFINET IO with int.
  • Page 8: Commissioning

    OHV-F230-B17 Commissioning Commissioning Connecting the gateway to the handheld reader 1. Connect the OHV1000-F223-R2 and OHV100-F222-R2 handheld readers to the gateway using the V19S-G-1.7/3M-PVC-V50 connection cable. 2. Connect the gateway to the power supply. 3. Scan the control code below using the handheld reader.
  • Page 9: Operation And Communication

    IO supervisor: Programming unit/PC with commissioning and diagnostic functions. 4.1.2 PROFINET IO Interface OHV-F230-B17 gateways are PROFINET IO devices that communicate cyclically with the assigned PROFINET IO controller during operation. The PROFINET interface of the OHV-F230-B17 gateway supports: A transfer rate of 100 Mbit/s...
  • Page 10: Project Planning Using Device Description

    OHV-F230-B17 Operation and Communication I&M Data I&M data 1 system ID location ID I&M data 2 installation date I&M data 3 additional information Figure 4.1 4.1.3 Project Planning Using Device Description As with PROFIBUS DP, a field device is integrated into the project planning tool by way of a device description.
  • Page 11 Inserting the function block and data module 1. Unzip the zip file. 2. In the module folder, mark the OHV-F230-B17 function block and the associated iDB_OHV- F230-B17 instance data block. Right-click on the marked entries and select Copy. 3. Right-click the destination project and select Insert.
  • Page 12 OHV-F230-B17 Operation and Communication Figure 4.3 Inserting PROFINET-IO system A PROFINET IO system is now available to which you can connect new nodes. 8. Drag the PROFINET module of the gateway from the catalog into the connection window and link it to the PROFINET IO system.
  • Page 13 OHV-F230-B17 Operation and Communication 9. To assign the gateway to the PROFINET module just inserted, select Destination system > Ethernet > Edit Ethernet node from the menu bar. In the window that opens, click Browse. A list opens containing all accessible nodes.
  • Page 14 OHV-F230-B17 Operation and Communication Figure 4.6 Editing Ethernet nodes 12.If the device name of the node from the list open previously is present in the section Assign device name (in this example ohv-f230), click Assign name. 13.Click Close. 14.Double-click the PROFINET module in the connection window and check whether the device name has been successfully transferred.
  • Page 15 OHV-F230-B17 Operation and Communication Figure 4.7 PROFINET module properties 15.Click OK. 16.To assign address areas for inputs and outputs, add the following modules from the catalog to the device: - Result counter - Result 64 byte Figure 4.8 PROFINET configuration tables...
  • Page 16: Profinet Address And Identifying A Device

    OHV-F230-B17 Operation and Communication 4.1.4 PROFINET Address and Identifying a Device Every PROFINET IO device has a unique device identification. This device identification consists of the following: A unique MAC address. This MAC address is printed on the back of the device.
  • Page 17 OHV-F230-B17 Operation and Communication Result 128 byte module Result message from the handheld reader Status byte 0 Status byte Status byte 1 Message length Data byte 0 Start of the scan result MSB first Data byte 1 Scan result Scan result...
  • Page 18: Appendix

    OHV-F230-B17 Appendix Appendix ASCII table ASCII ASCII ASCII hex ASCII Space " & < >...
  • Page 19 Twinsburg, Ohio 44087 · USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications / DOCT-5408 Copyright PEPPERL+FUCHS • Printed in Germany 12/2016...