Release Circuits; Wiring Overview Of Safety Monitor - Pepperl+Fuchs VBG-EN-K30-DMD-S16 Manual

Ethernet/ip gateway with integrated safety monitor
Table of Contents

Advertisement

7.8

Release circuits

7.8.1

Wiring overview of Safety Monitor

1.13
0 V
24 V
2.Y2
+
2.Y1
Aux
1.Y1
1.Y2
2.Y1
2.Y2
K1
K2
K3
K4
+
1.Y1
1.14
3.14
4.14
1.Y1 (EDM 1/Start 1), 2.Y1 (EDM 2/Start 2), 1.Y2 (EDM 3/Start 3),
2.Y2 (EDM 4/Start 4)
The safety unit provides 4 inputs. The EDM & START inputs can be defined freely.
The inputs may not be connected to other potentials, but rather only directly or
through potential-free switches to + (for EDM/START).
Switching current static 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 µs).
3.14, 4.14
Semiconductor outputs. Max. contact load: 0.5 A DC-13 at 30 V.
1.14, 2.14; 1.13, 2.13
Potential-free relay contacts. Safety relay with one contact set for read-back. Max.
contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V.
0 V, 24 V
Semiconductor outputs are powered by separate 24 V DC.
+ (for EDM/Start)
Output supply, powered by AS-i. May not be connected to other potentials, but
rather only directly or through potential-free switches to one of the EDM or START
inputs. Voltage 30 ... 15 V
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91
2.13
+
+
1.Y2
2.14
.
DC
AS-Interface
Electrical connection
© Pepperl+Fuchs, Printed in Germany
Internet http://www.pepperl-fuchs.com
41

Advertisement

Table of Contents
loading

Table of Contents