Pepperl+Fuchs VBG-EN-K30-DMD-S16 Manual page 69

Ethernet/ip gateway with integrated safety monitor
Table of Contents

Advertisement

Information!
If all safety AS-i slaves have been successfully taught, the first line in the display
changes from TEACHING CODES to CODES LEARNED.
All safety contacts (also in sequence) must be closed for the safety unit to learn
the code sequences. Incomplete code tables are not learned.
Press on ESC/Service to quit learning. It is then possible to restart the Monitor:
Information!
See also
<Procedure for configuring and teaching code sequences>.
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91
Operation in advanced display mode
TEACHING CODES
CLOSE CONTACTS
AS-I 1:
|1-OK
2-RX | 3-RR
.... |
30-DC |31-DC
AS-I 2:
| 1-OK
2-RX | 3-RR
.... |
30-DC |31-DC
....
HELP
NO SAFETY SL
MS MISSING SLAVE
X
CH OK
R
CH RELEASED
OK CODE LEARNED
ER CODE ERROR
DC DUPL.CODE
START MONITOR?
OK
AS-Interface
© Pepperl+Fuchs, Printed in Germany
Internet http://www.pepperl-fuchs.com