Commissioning / Inbetriebnahme
underlined data can be selected
unterstrichene Werte sind anwählbar
ETH ERNET/IP
ETHERNET/IP
CONFIGURED
TCP/OBJECT
ETHERNET OBJ.
NO DNS CLIENT
DHCP CLIENT
DHCP-DNS UPD
CFG SETTABLE
USE STORED VAL.
20 - F6 - 24 - 01
TCP/IP OBJECT
IF STATUS
IP ADDRESS
IF CAPABILITY
192.168.42.149
IF CONTROL
NETMASK
PATH TO LINK OBJ
255.255.255.0
TCP/IP CONFIG
GATEWAY
0 .0 .0 .0
ETHERNET OBJ.
IF SPEED
IF STATUS
PHYSICAL ADDR.
IF COUNTERS
100 Mbps
LINK ACTIVE
FULL DUPLEX
A/NEGO SUCCESS
RESET NEEDED
NO HW FAULT
12-34-56-78-9A-BC
:
QUICK SETUP
Q UICK SETUP
WARNING:
OUTPUTS MAY BE
RESET
STORE AS-I
CONFIGURATION
STORE + RUN
STORE + PRJ MODE
Basic Operation
The device starts in the traditional mode. You can switch between the two modes with ESC or OK. In the advanced mode the
cursor is moved by the arrow buttons. Pushing OK puts you to the superior menu (in the drawing one step to the right side). ESC
puts you back to the previous menu. To edit data move with arrow buttons the marking to desired line first and then select the
item with OK, change the data by using the arrow buttons and finally press OK button to accept the input. Pushing ESC cancels
the editing.
Grundlegende Bedienungshinweise
Das Gerät startet im klassischen Modus. Mit ESC oder OK kann zwischen dem klassischen und dem erweiterten Modus
gewechselt werden. Im erweiterten Modus wird der Cursor mit den Pfeil-Tasten bewegt. OK wechselt ins nächsthöhere Menü.
ESC wechselt zurück ins vorherige Menü. Die zu editierenden Werte zunächst mit dem Cursor markieren, dann mit OK
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-0 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91
classic mode / klassischer Modus
1.12A
advanced display mode / erweiterter Display-Modus
ETHERNET/IP
QUICK SETUP
AS-I SAFETY
DIAGNOSIS
SLAVE ADR TOOL
TEST
SETUP
DISP CONTRAST
SLAVE ADR 21A
OK
BINARY INPUTS
BINARY OUTPUTS
ANALOG INPUTS
1 +32767 OVERFL
ANALOG OUTPUTS
+1
0
+2
1
PARAM
PERM PARAM
CONFIG
PERM CONF
ANALOG IN 1
0 +2500
1 +17898
2 +32767 OVERFL
3 -20023
ANALOG OUT 1
0
+2500
1
+17898
AS-I CIRCUIT 1
2
+32767
AS-I CIRCUIT 2
3
-20023
SL AV E ADR TO O L
SLAVE ADR TOOL
SLAVE ADR TOOL
CONNECT NEW SLV
OLD ADDRESS
21A
NEW ADDRESS
03B
PRG
Operation in advanced display mode
AS-I CIRCUIT 1
AS-I CIRCUIT 2
SLAVE TEST TOOL
SLAVE ADR
TEST
1
1
BINARY INPUTS
0000
D3...D0
1A - 0 1 0 1
2A - 0 1 0 1
...
31A - 1 1 1 1
1B - 0 1 1 0
...
31B - 0 1 0 1
F
BINARY OUTPUTS
F
D3...D0
0A72
1A -
0 1 0 1
0A72
2A -
0 1 0 1
...
31A -
1 1 1 1
1B -
0 1 1 0
...
31B -
0 1 0 1
ANALOG INPUTS
1X (SINGLE SLAVE)
2A (A-SLAVE)
3B (B-SLAVE)
....
31
ANALOG OUTPUTS
1X (SINGLE SLAVE)
2A (A-SLAVE)
2B (B-SLAVE)
....
31
PARAMETERS
| 1A-
0
2A-
2
| 3A-
F
4A-
E
| 5A-
3
....
30A-
8
| 31A-
9
| 1B-
0
2B-
E
| 3B-
0
4B-
E
| 5B-
0
...
...
30B-
8
| 31B-
9
© Pepperl+Fuchs, Printed in Germany
Internet http://www.pepperl-fuchs.com
AS-Interface
WARNING:
OUTPUTS MAY BE
SET AND HOST MAY
LOOSE CONTROL.
SLAVE TE S T TOOL
SLAVE TEST TOOL
BINARY INPUTS
BINARY OUTPUTS
ANALOG INPUTS
ANALOG OUTPUTS
PARAMETERS