Diagnostics Trace Object - Festo CPX-FB36 Electronics Description

Terminal cpx
Hide thumbs Also See for CPX-FB36:
Table of Contents

Advertisement

C. EtherNet/IP Objects of the CPX-FB36
C.4.4 Diagnostics Trace Object
Attr.
Access
Name
No.
1
Get
2
Get
Days
3
Get
Hours
4
Get
Minutes
5
Get
Seconds
6
Get
Milliseconds
7
Get
Module
code
8
Get
Module
number
9
Get
Channel
number
1) d (diagnostic event) = 0 ... 39 ; most current diagnostic event = 0;
2) Measured from the time the power supply was switched on
3) If the error number = 0, the content is also 0. If the error number is between 128 ... 199
(error class 3), the content is not relevant (service case).
Tab. C/26: Attributes of the Diagnostics Trace Object - Part 1
C-24
Object class:
Instances:
An instance is created for each diagnostic entry.
Description
Marking the first entry after
Power on
Supplies 1 if it is the first
entry after Power on.
Number of days
Number of hours
Number of minutes
Number of seconds
Number of 10 msec
Module code of the module
3)
which registered the error
Module position of the
module which registered the
error; 63 = error not
module-related
Number of the first faulty
3)
channel
134
d
1 ... 40
Type
BYTE
2)
BYTE
2)
BYTE
2)
BYTE
2)
BYTE
2)
BYTE
BYTE
BYTE
BYTE
Festo P.BE-CPX-FB36-EN en 1309NH English
Function no.
1)
3488 + n
n = 10 * d + 4
(bit 7)
n = 10 * d + 0
n = 10 * d + 1
n = 10 * d + 2
n = 10 * d + 3
n = 10 * d + 4
(bits 0 ... 6)
n = 10 * d + 5
n = 10 * d + 6
(bits 6, 7)
n = 10 * d + 7
(bits 0 ... 5)