Festo CPX-FB36 Electronics Description page 123

Terminal cpx
Hide thumbs Also See for CPX-FB36:
Table of Contents

Advertisement

B. Address assignment of the CPX terminal
Input/output modules and system diagnostics
11. Number of analogue input modules CPX-4AE-TC
12. Number of analogue input modules CPX-4AE-P-...
13. Number of analogue output modules CPX-2AA-U-I + __ x 32 O
14. Number of inputs and outputs of other modules
(e.g. CP interface, VPPM-/MPA-P pneumatic
module)
15. Midi/Maxi, CPA-, MPA-L and VTSA/VTSA-F pneumatic interfaces:
Number of configured valve solenoid coils (+ 8 O ... 32 O; factory
configured presets are 32 O (Midi/Maxi, VTSA/VTSA-F/MPA-L) or
24 O (CPA))
16. Number of MPA1- or MPA2 pneumatic modules
17. Sum total of inputs/outputs to be configured
Total from 1 to 16 (max. 512 I and 512 O)
1) Number of occupied inputs /outputs
2) 4-off modules CPX-4DE and CPX-4DA as well as MPA2 pneumatic modules generally occupy 8
inputs or outputs (1 byte; available address space remains partially unused)
Tab. B/9:
Identifying the assigned address space (total of inputs and outputs) - Part 2
Festo P.BE-CPX-FB36-EN en 1309NH English
+ __ x 64 I
+ __ x 64 I
+ __ I/O
+ __ x 8 O
Tab. B/1
Inputs
+ ____ I
+ ____ I
+ ____ I
2)
= ____ I
Outputs
+ ____ O
+ ____ O
+ ____ O
+ ____ O
= ____ O
B-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents