D. Modbus/TCP Objects of the CPX-FB36
I/O diagnostics interface
Read access
15
14
13
12
Result of last request
Data from the system table
Result of last request:
= 0: Wait
= 8000
: Request successful
h
> 8000
: Error
h
8001
: Write protection or operator unit has write access
h
8002
: Writing not permitted, reserved range
h
8003
: Internal error
h
Tab. D/28: I/O diagnostics interface - Read access
Festo P.BE-CPX-FB36-EN en 1309NH English
11
10
9
8
Information on the I/O diagnostics interface and examples of
its use can be found in the CPX system description in the
chapter "Diagnostics and error handling".
7
6
5
4
3
2
1
0