C. EtherNet/IP Objects of the CPX-FB36
C.4.4 "Diagnosis Trace Object"
Attr.
Access
Description
no.
1
Get
2
Get
Days
3
Get
Hours
4
Get
Minutes
5
Get
Seconds
6
Get
Milliseconds
7
Get
Module code
8
Get
Module
number
9
Get
Channel
number
1) d (Diagnostic event) = 0 ... 39; current diagnostic event = 0;
2) Measured from the moment the power supply is switched on
3) If the error number = 0, the content of this byte is also 0.
If the error number lies between 128 ... 199 (error class 3), the content of this byte is not relevant
(servicing required).
Tab. C/26: Attributes of the diagnostics trace object - part 1
C-24
Object class:
Instances:
An instance is created for each diagnostic entry.
Description
Marking the first entry after
Power On
Supplies 1 if it is the first
entry after Power On.
Number of days
Number of hours
Number of minutes
Number of seconds
Number of 10 ms
3)
Module code of the module
which registered the error
Module position of the mod­
ule that signaled the error;
63 = Error not module-related
Number of the first faulty
3)
channel
134
d
1
40
...
Type
BYTE
2)
BYTE
2)
BYTE
2)
BYTE
2)
BYTE
2)
BYTE
BYTE
BYTE
BYTE
Festo CPX-FB36-EN en 1611a English
Function no.
1)
3488 + n
n = 10 × d + 4
(Bit 7)
n = 10 × d + 0
n = 10 × d + 1
n = 10 × d + 2
n = 10 × d + 3
n = 10 × d + 4
(Bit 0 ... 6)
n = 10 × d + 5
n = 10 × d + 6
(Bit 6, 7)
n = 10 × d + 7
(Bit 0 ... 5)