Festo CPX-FB36 Electronics Description page 197

Terminal cpx
Hide thumbs Also See for CPX-FB36:
Table of Contents

Advertisement

D. Modbus/TCP Objects of the CPX-FB36
Modbus
CPX-CP interface
1)
address
used strings 1, 2, 3, 4 (Line 1 ... 4)
Processing data inputs
Bit 15
12
n
Data byte 1
n+1
Data byte 3
n+2
Data byte 5
n+3
Data byte 7
n+4
Data byte 9
n+5
Data byte 11
n+6
Data byte 13
n+7
Data byte 15
n+8
Echo output data 1
n+9
Echo output data 3
n+10
Echo output data 5
n+11
Echo output data 7
n+12
Echo output data 9
n+13
Echo output data 11 Echo output data 10 –
n+14
Echo output data 13 Echo output data 12 –
n+15
Echo output data 15 Echo output data 14 –
n+16
Diagnostic data
1) n corresponds to the first Modbus address of the module.
Tab. D/25: CPX-CP interface
Festo P.BE-CPX-FB36-EN en 1309NH English
11
8
7
4
3
Data byte 0
Data byte 2
Data byte 4
Data byte 6
Data byte 8
Data byte 10
Data byte 12
Data byte 14
Echo output data 0
Echo output data 2
Echo output data 4
Echo output data 6
Echo output data 8
Processing data outputs
0
15
12
11
8
Data byte 1
Data byte 3
Data byte 5
Data byte 7
Data byte 9
Data byte 11
Data byte 13
Data byte 15
7
4
3
0
Data byte 0
Data byte 2
Data byte 4
Data byte 6
Data byte 8
Data byte 10
Data byte 12
Data byte 14
D-17