Process Data Objects (Pdos); Pdo Mapping Settings - Omron R88M-K Series User Manual

Ac servomotors/servo drives with built-in ethercat communications
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

5-4 Process Data Objects (PDOs)

5-4 Process Data Objects (PDOs)

The process data objects (PDOs) are used to transfer data during cyclic communications in
realtime. PDOs can be reception PDOs (RxPDOs), which receive data from the controller, or
transmission PDOs (TxPDOs), which send status from the Servo Drive to the host controller.
The EtherCAT application layer can hold multiple objects to enable transferring Servo Drive
process data. The contents of the process data are described in the PDO Mapping object and
the Sync manager PDO assignment object.
OMNUC G5-series Servo Drives support PDO mapping for position control.
5

PDO Mapping Settings

The PDO mapping indicates the mapping for application objects (realtime process data)
between the object dictionary and PDO. The number of mapped objects is described in sub-
index 0 of the mapping table. In this mapping table, 1600 hex to 17FF hex are for RxPDOs and
1A00 hex to 1BFF hex are for TxPDOs.
G5-series Servo Drives use 1701 hex for RxPDOs and 1B01 hex for the TxPDOs.
The following table is an example of PDO mapping.
5-5
RxPDO
Operation command, target position, etc.
Host
Controller
TxPDO
Operation status, actual position, etc
Object Dictionary
Index
Sub
Object contents
1ZZZh
01h
6TTTh TTh
1ZZZh
02h
6UUUh UUh
1ZZZh
03h
YYYYh YYh
6TTTh
TTh
Object A
6UUUh
UUh
Object B
6VVVh
VVh
Object C
6YYYh
YYh
Object D
6ZZZh
ZZh
Object E
OMNUC G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
8
8
16
PDO-Length: 32 bits
PDO_1
Object A Object B
Servo Drive
Object D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents