3-1 Servo Drive Specifications
R88D-KN30F-ECT-R/R88D-KN50F-ECT-R
Main Circuit Terminal Block Specifications (TB1)
Symbol
24 V
0 V
Main Circuit Terminal Block Specifications (TB2)
Symbol
3
L1
L2
L3
B1
B2
B3
NC
U
V
W
Tighten the terminal block screws to the torque of 0.75 N•m (M4) or 1.5 N•m (M5).
If the torque for terminal block screws exceeds 1.2 N•m (M4) or 2.0 N•m (M5), the terminal block
may be damaged.
Tighten the fixing screw of the terminal block cover to the torque of 0.2 N•m (M3).
Tighten the ground screws to the torque of 0.7 to 0.8 N•m (M4) or 1.4 to 1.6 N•m (M5).
3-11
Name
Control circuit power
supply input
Name
Main circuit power supply
input
External Regeneration
Resistor connection
terminals
Motor connection
terminals
Precautions for Correct Use
OMNUC G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
Function
24 VDC ± 15%
Function
R88D-KN@F-ECT-R (3 to 5 kW):
3-phase 380 to 480 VAC (323 to 528 V) 50/60 Hz
Normally B2 and B3 are connected.
If there is high regenerative energy, remove the short-circuit bar
between B2 and B3 and connect an External Regeneration
Resistor between B1 and B2.
Do not connect.
Phase U
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
Phase V
Phase W