Omron R88M-K Series User Manual page 360

Ac servomotors/servo drives with built-in ethercat communications
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

9-6 Extended Objects
Overspeed Detection Level Setting
3513 hex
Setting
range
Size
Set the overspeed detection level.
The overspeed detection level setting is 1.2 times the maximum motor rotation speed if this object
is set to 0.
This object should normally be set to 0. The setting should be changed only when it is necessary
to lower the overspeed detection level.
The set value of this object is limited to 1.2 times the maximum motor rotation speed.
The detection margin of error for the set value is ±3 r/min for a 5-core absolute encoder and
±36 r/min for a 5-core incremental encoder.
Overrun Limit Setting
3514 hex
Setting
range
Size
Set the allowable operating range for the position command input range.
If the set value is exceeded, and Overrun Limit Error (Error No. 34.0) will occur.
Refer to 7-3 Overrun Protection on page 7-9.
Control Input Signal Read Setting
3515 hex
Setting
range
Size
Select the signal read cycle for control input (digital input).
9
The External Latch Inputs 1, 2 and 3 (EXT1, 2, and 3) are excluded.
Explanation of Set Values
value
9-35
0 to 20000
Unit
2 bytes (INT16)
0 to 1000
Unit
2 bytes (INT16)
0 to 3
Unit
2 bytes (INT16)
Set
0
0.250 ms
1
0.500 ms
2
1.5 ms
3
2.5 ms
OMNUC G5-series AC Servomotors and Servo Drives User's Manual (with Built-in EtherCAT Communications)
Default
r/min
setting
Access
RW
Default
0.1 rotation
setting
Access
RW
Default
setting
Access
RW
Description
All
Data
0
attribute
PDO map
Not possible.
csp
Data
10
attribute
PDO map
Not possible.
All
Data
0
C
attribute
PDO map
Not possible.
A
A

Hide quick links: