Device Commands For Operating System Control - Lenze C750 Commissioning

Hide thumbs Also See for C750:
Table of Contents

Advertisement

10.6

Device commands for operating system control

The control section provides device commands which directly influence Windows 10 IoT. The
current status of Windows 10 IoT can also be detected and used in the PLC program.
Device commands for controlling Windows 10 IoT
Windows can be directly influenced via the device commands. The functions "Shutdown" and
"Restart" are identical to the functions "shutdown /s" and "shutdown /r" which can be directly
executed under Windows.
The return value directly informs about the status of the execution.
Power-on
40x2050:001
Shutdown
40x2050:002
Restart
40x2050:003
Reset
40x2050:005
Device status for Windows 10 IoT
The current status of Windows can be detected. The information can be used in the PLC
program for monitoring purposes.
Parameter
Address
Name / setting range / [default setting]
0x2050:001
GPOS control: Boot
0 Off / ready
1 On / start
2 In progress
3 Invalid state change
4 No access
0x2050:002
GPOS control: Shutdown
0 Off / ready
1 On / start
2 In progress
3 Invalid state change
4 No access
0x2050:003
GPOS control: Reboot
0 Off / ready
1 On / start
2 In progress
3 Invalid state change
4 No access
0x2050:005
GPOS control: Reset
0 Off / ready
1 On / start
2 In progress
3 Invalid state change
4 No access
40x2051:001
Information
Only status feedback
Execute the "Start Windows" device command.
• When the device command has been executed successfully, the value
Only status feedback
Only status feedback
Execute the "Shutdown Windows" device command.
• When the device command has been executed successfully, the value
Only status feedback
Only status feedback
Execute the "Restart Windows" device command.
• When the device command has been executed successfully, the value
Only status feedback
When this device command is executed, the CPU for Windows 10 IoT is
reset.
Note!
Executing this device command can cause errors in the Windows 10 IoT
operating system because Windows 10 IoT is not shut down properly.
Thus, this device command should only be executed if Windows 10 IoT
cannot be operated anymore.
Only status feedback
Execute the "Reset Windows" device command.
• When the device command has been executed successfully, the value
Only status feedback
Open system functionality
Device commands for operating system control
0 is shown.
0 is shown.
0 is shown.
0 is shown.
91