Status values
6.3

Positions

84
Unit of
%
measurement
D/A monitor output
not possible
Remark:
Motor pulse utilization,
Stated in & of the motor pulse current.
Dynamic motor utilization with reference to the nominal motor current
resp., in the case of a selected motor reference point, with reference to
the motor reference current. For the monitoring the impulse current and
the impulse current time are required in order to calculate a time
constant. 1.15*I can be set permanently. Error object 500.6 Bit 6, Error
Code 7180
Status of long-term motor utilization
Available in technology function:
Unit of
%
measurement
D/A monitor output
not possible
Remark:
Motor utilization,
Stated in & of the motor pulse current.
Effective motor utilization with reference to the nominal motor current
resp. if a motor reference point is selected, with reference to the motor
reference current. For the monitoring the thermal time constant Tau is
required. 1.05*I can be set permanently. Error object 500.1 Bit 13, Error
Code 2311
Status target position
Available in technology function:
Unit of
Unit
measurement
D/A monitor output
possible
Remark:
Stated in user units, reset position
Status actual position
Available in technology function:
Unit of
Unit
measurement
D/A monitor output
possible
Remark:
Stated in user units, reset position
Status of tracking error
Available in technology function:
Unit of
Unit
measurement
D/A monitor output
possible
Remark:
Stated in user units, difference between target and actual value of
position
Status target position without absolute reference
I11 T11 192-120101 N6 - March 2004
User level
D/A monitor: measurement unit of
the reference value
User level
D/A monitor: measurement unit of
the reference value
User level
D/A monitor: measurement unit of
the reference value
User level
D/A monitor:
measurement unit of the
reference value
User level
D/A monitor: measurement unit of
the reference value
standard
-
Object 683.3
T10, T11, T30, T40
standard
-
Object 680.4
T11, T30, T40
standard
Revolutions
Object 680.5
T11, T30, T40
standard
Revolutions
Object 680.6
T11, T30, T40
standard
Revolutions
Object 680.12