Ballast Resistor / High Voltage Supply Plug X2 For 400Vac Devices; Ballast Resistor / High Voltage Supply Plug X2 For 400Vac Devices - Parker Compax3 Series Operating Instructions Manual

Positioning via digital i/os
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Parker EME
Caution!
3.1.5.
Ballast resistor / high voltage supply plug X2 for 400VAC
devices
Brake operation Compax3 Sxxx V2
Controller type
Capacitance / storable energy
Minimum ballast - resistance
Recommended nominal power rating
Pulse power rating for 1s
The power voltage DC of two Compax3 V2 devices (230V devices) must not
be connected.
PIN
Description
1
+ Ballast resistor
2
- Ballast resistor
3
PE
4
+ DC high voltage supply
5
- DC high voltage supply
Caution! The connector assignment of X2 is changed!
Please note the screen printing on the front plate of the
device: this is valid
Compax3 Sxxx V4 brake operation
Controller type
Capacitance / storable
energy
Minimum ballast -
resistance
Recommended nominal
power rating
Pulse power rating for 1s
I11 T11 192-120101 N6 - March 2004
Plug and connector assignment Compax3

Ballast resistor / high voltage supply plug X2 for 400VAC devices

S025 V2
560µF / 15Ws
100Ω
20 ... 60W
1kW
S038 V4
S075 V4
235µF / 37Ws 470µF / 75Ws 690µF /
100Ω
56Ω
60 ... 250W
60 ... 500 W
2.5kW
5kW
S063 V2
1120µF /30Ws
56Ω
60 ... 180W
2.5kW
S150 V4
S300 V4
1100µF /
110Ws
176Ws
22Ω
15Ω
60 ... 1000 W
60 ... 1000 W
10 kW
42kW
23