Parker EME
Overview:
4.1.9.2
Positioning data
record:
NO STOP: I0: no STOP
START: I1: START-Signal (with edge)
A new START resumes the positioning process at the position where it was
interrupted.
Relationship between the chosen STOP function and the positioning mode
A START flank after previous STOP produces:
- on condition that no STOP (E0=24V) is still present -
STOP and termination of
the current positioning
procedure
(STOP with termination)
STOP and interruption of
the current positioning
procedure (STOP
without termination)

Define positioning data records

1
2
3
4
5
I11 T11 192-120101 N6 - March 2004
Single positioning
The positioning data record
address is read in and the
positioning data record is
executed.
Note : In continuous mode a
complete positioning, starting
from the current position, takes
place to the target position
contained in the data record.
The positioning procedure which was active before the STOP
is continued irrespective of the set positioning data record
address.
t
t
t
t
Setting up Compax3
Sequential positioning
The positioning data
record address is read in
and a new sequential
positioning procedure is
started.
59