6.9

Transmitter

Status of sine in signal processing
Available in technology function:
Unit of
n/a
measurement
D/A monitor output
not possible
Remark:
Sinus trace resolver, für F10 devices
The value 1 corresponds to 2.5 Volts
The amplitude must be <1 and > 0.1 at the resolver; otherwise a level
error is reported.
Status of cosine in signal processing
Available in technology function:
Unit of
n/a
measurement
D/A monitor output
not possible
Remark:
Cosine trace of resolver, for F10 devices
The value 1 corresponds to 2.5 Volts
The amplitude must be <1 and > 0.1 at the resolver; otherwise a level
error is reported.
Status of analog input sine
Available in technology function:
Unit of
n/a
measurement
D/A monitor output
not possible
Remark:
Sine trace of encoder, für F11 and F12 devices (0.5 = 2.5V)
Status of analog input cosine
Available in technology function:
Unit of
n/a
measurement
D/A monitor output
not possible
Remark:
Cosine trace of encoder, für F11 and F12 devices
Status of feedback level
Available in technology function:
Unit of
V
measurement
D/A monitor output
not possible
Remark:
Feedback level, for F11 and F12 devices, display in Vpp
(=sqrt(sin²+cos²))
I11 T11 192-120101 N6 - March 2004
User level
D/A monitor:
measurement unit of the
reference value
User level
D/A monitor:
measurement unit of the
reference value
User level
D/A monitor:
measurement unit of the
reference value
User level
D/A monitor:
measurement unit of the
reference value
User level
D/A monitor:
measurement unit of the
reference value
Status values
Object 692.1
T10, T11, T30, T40
advanced
-
Object 692.2
T10, T11, T30, T40
advanced
-
Object 692.3
T10, T11, T30, T40
advanced
-
Object 692.4
T10, T11, T30, T40
advanced
-
Object 692.5
T10, T11, T30, T40
advanced
-