4.1.10. RS485 setting values

Multicast address
Device address
Baud rate
Protocol
62

Dynamic positioning

You can change the positioning data record during a positioning procedure.
Thereby the following conditions apply:
Acceleration and deceleration remain constant irrespective of the values set in
!
the new positioning data record.
The jerk, too, remains constant.
!
The speed of the new positioning data record becomes active.
!
The drive runs to the target position specified in the new positioning data record.
!
The new positioning data record address must not be 0.
!
Pos 1
Pos 5
V 1
V 5
START
E/I3 - E/I6 -1-
If "Master=Pop" was selected, only the settings compatible with the Pops (Parker
Operator Panels) made by Parker are possible.
Please note that the connected Pop has the same RS485 setting values.
You can test this with the "PopDesigner" software.
"Master=General" makes all Compax3 settings possible.
You can use this address to allow the master to access multiple devices
simultaneously.
The device address of the connected Compax3 can be set here.
Adjust the transfer speed (baud rate) to the master.
Adjust the protocol settings to the settings of your master.