Positioning; Operating Modes - Parker Compax3 Series Operating Instructions Manual

Positioning via digital i/os
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Parker EME
4.1.9.

Positioning

Function
Condition START
edge
Reaction time
4.1.9.1
Absolute mode
Positioning takes place with 31 positioning data records (15 when operating with
machine zero) which are defined via address, mode (POSA,POSR), target position,
speed, acceleration, deceleration (delay) and number of repetitions.
The desired positioning data record is selected via the inputs (I3-I7) and started via
a START edge.
The positioning data record address is thereby read in with the START edge.
Minimum pulse duration: 1ms
Maximum 1.4ms (0.4 - 1.4ms)

Operating modes

Operating mode: absolute mode or endless mode
A fixed measuring system is associated with the travel range: A fixed defined zero
point exists. All positions are referred to this zero point.
0
-300
-200
-100
+100
I11 T11 192-120101 N6 - March 2004
+200
+300
Setting up Compax3
55